Evaluation of a Photoelectric Clot Timer for the Performance of Prothrombin Times.

نویسنده

  • S WINSTEN
چکیده

This report consists of an evaluation of a commercially available photoelectric clot timer which can be used for performing prothrombin times. In the last two years, approximately 40,000 determinations have been satisfactorily performed with this apparatus. In addition, with the use of the timer, we have been able to pick up unsuspected fibrinogen deficiencies during the course of the performance of routine prothrombin times.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photoelectric determination of plasma clotting times.

A photoelectric clot timer is described. The apparatus allows a large analytic capacity, with good precision and correlation to manual methods, and can be used with capillary blood. Prothrombin analysis according to the method of Quick and Owren, the Thrombotest method, and determinations of partial thromboplastin time are applicable to the apparatus. The semiautomated procedure is extremely si...

متن کامل

Evaluation of Prothrombin Time in Acute Acetaminophen Overdose treated by N-acetylcysteine

Background: Acetaminophen (N-Acetyl-p aminophenol; APAP) is one of the most common types of analgesics. It is also the most common xneobitic reported to poison centers. This study investigates if therapeutic doses of NAC can falsely increase coagulation tests, prothrombin time (PT) and bleeding time (BT). ​​ Methods: Thirty-six APAP poisoned patients whose acetaminophen serum concentration were...

متن کامل

Factor V Leiden, MTHFR C677T and Prothrombin Gene Mutation G20210A in Iranian Patients with Venous Thrombosis

Background: Factor V Leiden, Prothrombin gene (G20210A) and MTHFR (C677T) polymorphism are the main biomarkers for evaluation of tendency for venous thromboembolism. We aimed to investigate the frequency of mutations in factor V Leiden, Prothrombin G20210A and MTHFR C677T and identify the genetic status for these mutations in patients with venous thrombosis. Methods: This study was carried out...

متن کامل

Effects of Methylglyoxal and Aspirin on In Vitro Coagulation and Clot Permeability

Backgrounds and Aims: Methylglyoxal (MGO) is an –α, β dicarbonyl aldehyde inevitably produced from triose-phosphate intermediates of glycolysis, and amino acid. Increased MGO in blood leads to alterations in coagulation, clot permeability and thus, atherosclerosis in children with diabetes; however, the precise mechanism is not clear. The present study aimed to compare differen...

متن کامل

بررسی شیوع لخته دهلیز و گوشک دهلیز چپ در بیماران مراجعه کننده با فلوتر دهلیزی بر حسب بیماری زمینه‌ای

Introduction: Most current evidence suggests the risk of left atrial and or auricular thrombi(LA &LAA) in patients with atrial flutter rhythm is similar to patients with atrial fibrillation, but there is still uncertainty in the risk level and the patient's need to receive anticoagulant therapy. Different studies report various frequencies for atrial thrombi and left atrial spontaneous echo-con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 11  شماره 

صفحات  -

تاریخ انتشار 1965