Artemis very high frequency digital ultrasound-guided femtosecond laser recut after flap complication.

نویسندگان

  • Dan Z Reinstein
  • Zachary Dickeson
  • Timothy J Archer
  • Marine Gobbe
چکیده

Incomplete flaps are a relatively uncommon complication of laser-assisted in situ keratomileusis (LASIK) that occur when creation of the corneal flap is interrupted. Further complications can arise if a second flap is created that intersects the original flap interface, resulting in tissue slivers that can lead to more complications and poor visual outcomes. We report the case of a 56-year-old man who underwent LASIK in which an incomplete flap occurred after 45% completion using a mechanical microkeratome with a 160 µm head. The maximum depth achieved by this incomplete flap was measured by very high-frequency (VHF) digital ultrasound as 182 μm peripherally. Two months later, a second flap was created beneath the incomplete flap, at a depth of 190 μm. The resulting flap had a central thickness of 196 μm and a minimum clearance of 30 μm beneath the incomplete flap. This demonstrates a method for creating secondary flaps that may significantly reduce the risk of flap interface intersection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Repeatability of layered corneal pachymetry with the artemis very high-frequency digital ultrasound arc-scanner.

PURPOSE To assess the three-dimensional repeatability of thickness measurements for epithelium, stroma, cornea, flap, and residual stromal bed using the Artemis very high-frequency (VHF) digital ultrasound arc-scanner (ArcScan Inc). METHODS Five consecutive measurements were obtained for 10 eyes of 10 patients 1 year after LASIK using the Artemis VHF digital ultrasound arc-scanner across the ...

متن کامل

Change in epithelial thickness profile 24 hours and longitudinally for 1 year after myopic LASIK: three-dimensional display with Artemis very high-frequency digital ultrasound.

PURPOSE To longitudinally follow epithelial thickness profile changes after myopic LASIK for 1 year to determine when and how epithelial changes occur and when epithelial stability is reached. METHODS Epithelial thickness was measured with Artemis very high-frequency digital ultrasound (ArcScan Inc) across the central 10-mm corneal diameter in 11 eyes before and 1 day, and 1, 3, 6, and 12 mon...

متن کامل

Confocal microscopy of a femtosecond laser LASIK flap before separation.

PURPOSE To describe stromal changes after a femtosecond laser laser-assisted in situ keratomileusis (LASIK) flap was created but not separated. DESIGN Case report. METHODS As part of a randomized paired-eye study comparing LASIK flap creation by a femtosecond laser to a mechanical microkeratome, a femtosecond laser flap was successfully created on one eye of one patient, but the flap was no...

متن کامل

Arc-scanning very high-frequency digital ultrasound for 3D pachymetric mapping of the corneal epithelium and stroma in laser in situ keratomileusis.

PURPOSE To test and demonstrate measurement precision, imaging resolution, 3D thickness mapping, and clinical utility of a new prototype 3D very high-frequency (VHF) (50 MHz) digital ultrasound scanning system for corneal epithelium, flap, and residual stromal thickness after laser in situ keratomileusis (LASIK). METHODS VHF ultrasonic 3D data was acquired by arc-motion, meridional scanning w...

متن کامل

Three-dimensional LASIK flap thickness variability: topographic central, paracentral and peripheral assessment, in flaps created by a mechanical microkeratome (M2) and two different femtosecond lasers (FS60 and FS200)

PURPOSE To evaluate programmed versus achieved laser-assisted in situ keratomileusis (LASIK) flap central thickness and investigate topographic flap thickness variability, as well as the effect of potential epithelial remodeling interference on flap thickness variability. PATIENTS AND METHODS Flap thickness was investigated in 110 eyes that had had bilateral myopic LASIK several years ago (av...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Digital journal of ophthalmology : DJO

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 2014