Accuracy of a Wrist-Worn Wearable Device for Monitoring Heart Rates in Hospital Inpatients: A Prospective Observational Study

نویسندگان

  • Ryan R Kroll
  • J Gordon Boyd
  • David M Maslove
چکیده

BACKGROUND As the sensing capabilities of wearable devices improve, there is increasing interest in their application in medical settings. Capabilities such as heart rate monitoring may be useful in hospitalized patients as a means of enhancing routine monitoring or as part of an early warning system to detect clinical deterioration. OBJECTIVE To evaluate the accuracy of heart rate monitoring by a personal fitness tracker (PFT) among hospital inpatients. METHODS We conducted a prospective observational study of 50 stable patients in the intensive care unit who each completed 24 hours of heart rate monitoring using a wrist-worn PFT. Accuracy of heart rate recordings was compared with gold standard measurements derived from continuous electrocardiographic (cECG) monitoring. The accuracy of heart rates measured by pulse oximetry (Spo2.R) was also measured as a positive control. RESULTS On a per-patient basis, PFT-derived heart rate values were slightly lower than those derived from cECG monitoring (average bias of -1.14 beats per minute [bpm], with limits of agreement of 24 bpm). By comparison, Spo2.R recordings produced more accurate values (average bias of +0.15 bpm, limits of agreement of 13 bpm, P<.001 as compared with PFT). Personal fitness tracker device performance was significantly better in patients in sinus rhythm than in those who were not (average bias -0.99 bpm vs -5.02 bpm, P=.02). CONCLUSIONS Personal fitness tracker-derived heart rates were slightly lower than those derived from cECG monitoring in real-world testing and not as accurate as Spo2.R-derived heart rates. Performance was worse among patients who were not in sinus rhythm. Further clinical evaluation is indicated to see if PFTs can augment early warning systems in hospitals. TRIAL REGISTRATION ClinicalTrials.gov NCT02527408; https://clinicaltrials.gov/ct2/show/NCT02527408 (Archived by WebCite at  http://www.webcitation.org/6kOFez3on).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of wearable devices for post-discharge monitoring of ICU patients: a feasibility study

Background Wearable devices generate signals detecting activity, sleep, and heart rate, all of which could enable detailed and near-continuous characterization of recovery following critical illness. Methods To determine the feasibility of using a wrist-worn personal fitness tracker among patients recovering from critical illness, we conducted a prospective observational study of a convenienc...

متن کامل

Enoxaparin Utilization Evaluation: An Observational Prospective Study in Medical Inpatients

Drug utilization evaluation (DUE) is an effective program to identify variability in drug use and to support interventions that will improve patient outcomes. The appropriate use of enoxaparin, a low molecular weight heparin (LMWH), which is widely used as curative or preventive treatment of thromboembolic disorders was assessed in the study. A prospective DUE was carried out at Masih Daneshvar...

متن کامل

Enoxaparin Utilization Evaluation: An Observational Prospective Study in Medical Inpatients

Drug utilization evaluation (DUE) is an effective program to identify variability in drug use and to support interventions that will improve patient outcomes. The appropriate use of enoxaparin, a low molecular weight heparin (LMWH), which is widely used as curative or preventive treatment of thromboembolic disorders was assessed in the study. A prospective DUE was carried out at Masih Daneshvar...

متن کامل

Development of a Sleep Monitoring System with Wearable Vital Sensor for Home Use

This paper describes a new sleep monitoring system for home use. The basic system consists of a wearable physiological sensor and PC software for analyzing sleep quality from user’s wrist motion and heart rate variability. Different from a conventional sleep monitoring device used in a hospital, the sensor is so small and easy-to-use that a normal person can use it at home. This means that the ...

متن کامل

Estimating Heart Rate, Energy Expenditure, and Physical Performance With a Wrist Photoplethysmographic Device During Running

BACKGROUND Wearable sensors enable long-term monitoring of health and wellbeing indicators. An objective evaluation of sensors' accuracy is important, especially for their use in health care. OBJECTIVE The aim of this study was to use a wrist-worn optical heart rate (OHR) device to estimate heart rate (HR), energy expenditure (EE), and maximal oxygen intake capacity (VO2Max) during running an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2016