Foreign Body Response to Intracortical Microelectrodes Is Not Altered with Dip-Coating of Polyethylene Glycol (PEG)

نویسندگان

  • Heui C. Lee
  • Janak Gaire
  • Seth W. Currlin
  • Matthew D. McDermott
  • Kinam Park
  • Kevin J. Otto
چکیده

Poly(ethylene glycol) (PEG) is a frequently used polymer for neural implants due to its biocompatible property. As a follow-up to our recent study that used PEG for stiffening flexible neural probes, we have evaluated the biological implications of using devices dip-coated with PEG for chronic neural implants. Mice (wild-type and CX3CR1-GFP) received bilateral implants within the sensorimotor cortex, one hemisphere with a PEG-coated probe and the other with a non-coated probe for 4 weeks. Quantitative analyses were performed using biomarkers for activated microglia/macrophages, astrocytes, blood-brain barrier leakage, and neuronal nuclei to determine the degree of foreign body response (FBR) resulting from the implanted microelectrodes. Despite its well-known acute anti-biofouling property, we observed that PEG-coated devices caused no significantly different FBR compared to non-coated controls at 4 weeks. A repetition using CX3CR1-GFP mice cohort showed similar results. Our histological findings suggest that there is no significant impact of acute delivery of PEG on the FBR in the long-term, and that temporary increase in the device footprint due to the coating of PEG also does not have a significant impact. Large variability seen within the same treatment group also implies that avoiding large superficial vasculature during implantation is not sufficient to minimize inter-animal variability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Resistive and reactive changes to the impedance of intracortical microelectrodes can be mitigated with polyethylene glycol under acute in vitro and in vivo settings

The reactive response of brain tissue to implantable intracortical microelectrodes is thought to negatively affect their recordable signal quality and impedance, resulting in unreliable longitudinal performance. The relationship between the progression of the reactive tissue into a glial scar and the decline in device performance is unclear. We show that exposure to a model protein solution in ...

متن کامل

Synthesis, Characterization and renal toxicity of ZnO and polyethylene glycol Coated ZnO nanoparticles

Objective(s): The wide scale use of Zinc oxide nanoparticles (ZnO NPs) in the consumer market world makes human beings more prone to the exposure to ZnO nanoparticles and its adverse effects. Therefore, the aim of the present study is to assess renal toxicity potential of ZnO and Polyethylene glycol Coated ZnO Nanoparticles in rat.Materials and Methods: Co-precipitation chemical method was used...

متن کامل

Glial cells, but not neurons, exhibit a controllable response to a localized inflammatory microenvironment in vitro

The ability to design long-lasting intracortical implants hinges on understanding the factors leading to the loss of neuronal density and the formation of the glial scar. In this study, we modify a common in vitro mixed cortical culture model using lipopolysaccharide (LPS) to examine the responses of microglia, astrocytes, and neurons to microwire segments. We also use dip-coated polyethylene g...

متن کامل

Fabrication of Clotrimazole microparticles using polyethylene glycol 6000 and beeswax

Backgrounds: Microparticles are one of drug delivery systems designed for sustained and controlled release of drugs for a long period of time. Clotrimazole is a broad-spectrum antifungal agent, which is generally used for treatment of Candida albicans and others fungal infections. Objectives: The present study aims to fabricate Clotrimazole microparticles using beeswax (lipophilic coating) an...

متن کامل

Surface Coating of Red Blood Cells with Monomethoxy poly(ethylene glycol) Activated with Two Different Reagents

Methoxy poly(ethylene glycol) (mPEG) with molecular mass of 5 kDa activated with succinimidyl carbonate and cyanuric chloride, separately was covalently attached to human red blood cells (RBCs). Inhibition of agglutination by blood-type specific antisera (anti-D) was employed to evaluate the effect of the polymer coating. The remaining single cells after incubation with anti-D sera were cou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017