Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters.

نویسندگان

  • A F Stalder
  • M F Russe
  • A Frydrychowicz
  • J Bock
  • J Hennig
  • M Markl
چکیده

Quantification of CINE phase contrast (PC)-MRI data is a challenging task because of the limited spatiotemporal resolution and signal-to-noise ratio (SNR). The method presented in this work combines B-spline interpolation and Green's theorem to provide optimized quantification of blood flow and vessel wall parameters. The B-spline model provided optimal derivatives of the measured three-directional blood velocities onto the vessel contour, as required for vectorial wall shear stress (WSS) computation. Eight planes distributed along the entire thoracic aorta were evaluated in a 19-volunteer study using both high-spatiotemporal-resolution planar two-dimensional (2D)-CINE-PC ( approximately 1.4 x 1.4 mm(2)/24.4 ms) and lower-resolution 3D-CINE-PC ( approximately 2.8 x 1.6 x 3 mm(3)/48.6 ms) with three-directional velocity encoding. Synthetic data, error propagation, and interindividual, intermodality, and interobserver variability were used to evaluate the reliability and reproducibility of the method. While the impact of MR measurement noise was only minor, the limited resolution of PC-MRI introduced systematic WSS underestimations. In vivo data demonstrated close agreement for flow and WSS between 2D- and 3D-CINE-PC as well as observers, and confirmed the reliability of the method. WSS analysis along the aorta revealed the presence of a circumferential WSS component accounting for 10-20%. Initial results in a patient with atherosclerosis suggest the potential of the method for understanding the formation and progression of cardiovascular diseases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Methodology for Optimal Quantitative Flow Analysis by planar analysis of CINE Phase Contrast 2D or 3D MR data

Introduction: Time-resolved (CINE) phase contrast (PC) MRI allows measurement of time resolved threedirectional velocities within entire 3D vascular structures [1, 2]. The information contained in the PC data is not limited to volumetric flow, but also includes derived quantities such as wall shear stress (WSS), the viscous drag of blood on the arterial wall, which is believed to play a key rol...

متن کامل

Advanced Quantitative Flow and Wall Shear Stress Analysis at 3T: 2D Vs 3D Time-Resolved MR Velocity Mapping

Introduction: Time-resolved (CINE) phase contrast (PC) MRI permits the assessment of blood flow within entire 3D vascular structures [1, 2]. The resulting high-dimensional datasets (3 spatial dimensions, 3 velocity directions, and time) require new visualization and quantification methods to derive reliable clinical parameters. In this context, an advanced flow quantification tool was developed...

متن کامل

Reproducibility of quantitative analysis of aortic 4D flow data

Background 3D cine phase-contrast CMR ("4D Flow”) permits quantitative assessment of anomalous alterations of aortic blood flow. Two hemodynamic parameters that have been used for this purpose is the wall shear stress (WSS), which is known to regulate endothelial cell function, and the normalized flow displacement from the vessel center, which was recently shown to correlate with increased grow...

متن کامل

Improved assessment of aortic 3D blood flow with combined k-t accelerated 3D CINE bSSFP & 4D flow MRI

Background To determine hemodynamic parameters from 4D flow MRI, vessel boundaries are typically depicted by calculating a 3D phase contrast MR angiogram (PC-MRA) from 4D flow magnitude and flow images. However, this approach is limited by 1) low blood-tissue contrast of the magnitude images and 2) velocity weighting of PC-MRA may not fully depict areas of slow or swirling (vortex) flow. As a r...

متن کامل

Comparison of 4D flow and 2D PC MRI blood flow quantification in children and young adults with congenital heart disease

Background Echocardiography (echo) is the primary imaging modality for assessment of aortic and pulmonary blood flow velocities. 2D phase contrast (PC) MRI provides better access to all segments of the aortic and pulmonary system and is considered the standard for evaluating blood flow. Both techniques are limited by velocity analysis in 2D planes and by single-direction velocity measurement wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 60 5  شماره 

صفحات  -

تاریخ انتشار 2008