Quantitative evaluation of PET respiratory motion correction using real- time PET/MR simulated data

نویسندگان

  • Irene Polycarpou
  • Charalampos Tsoumpas
  • Andrew King
  • Paul K Marsden
چکیده

King’s College London, Division of Imaging Sciences and Biomedical Engineering, London, UK The impact of respiratory motion correction on quantitative accuracy in PET imaging is evaluated using real-time simulations for variable patient specific characteristics such as tumor malignancy and respiratory pattern. Respiratory patterns from real patients were acquired, with long quiescent motion periods (type-1) as commonly observed in most of the patients and with long term amplitude variability as it is expected under conditions of difficult breathing (type-2). The respiratory patterns were combined with an MR-derived motion model to simulate real-time 4D PET/MR datasets. Lung and liver tumors were simulated with diameters ranging of 10 and 12 mm and tumor to background ratio ranging from 3:1 to 6:1. Projection data for 6 and 3 mm PET resolution were generated for Philips Gemini scanner and reconstructed without and with motion correction using OSEM (2 iterations, 23 subsets). Motion correction was incorporated into the reconstruction process based on MR-derived motion fields. Tumors peak standardized uptake values (SUVpeak) were calculated from thirty noise realizations. Respiratory motion correction improves the quantitative performance with the greatest benefit observed for patients of breathing type-2. For breathing type-1 after applying motion correction SUVpeak of 12 mm liver tumor with 6:1 contrast was increased by 46% for a current PET resolution (i.e. 6 mm) and 47% for a higher PET resolution (i.e. 3 mm). Furthermore, the benefit of higher scanner resolution is small for torso imaging unless motion correction is applied. In particular, for large liver tumor (12 mm) with low contrast (3:1) after motion correction the SUVpeak was 34% increased for 6 mm resolution and 50% increased for a higher PET resolution (i.e. 3 mm resolution. This investigation indicates high impact of respiratory motion correction on tumor quantitative accuracy and its importance in order to benefit from the increased resolution of future PET scanners.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Respiratory motion correction of PET using MR-constrained PET-PET registration

BACKGROUND Respiratory motion in positron emission tomography (PET) is an unavoidable source of error in the measurement of tracer uptake, lesion position and lesion size. The introduction of PET-MR dual modality scanners opens a new avenue for addressing this issue. Motion models offer a way to estimate motion using a reduced number of parameters. This can be beneficial for estimating motion f...

متن کامل

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

Reducing the respiratory motion artifacts in PET cardiology: A simulation study

  Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...

متن کامل

Respiratory and cardiac motion correction in dual gated PET/MR imaging

LaTIM, INSERM, UMR 1101, Brest, France Respiratory and cardiac motion in PET/MR imaging leads to reduced quantitative and qualitative image accuracy. Correction methodologies involve the use of double gated acquisitions which lead to low signal-to-noise ratio (SNR) and to issues concerning the combination of cardiac and respiratory frames. The objective of this work is to use a generalized reco...

متن کامل

Motion correction strategies for integrated PET/MR.

UNLABELLED Integrated whole-body PET/MR facilitates the implementation of a broad variety of respiratory motion correction strategies, taking advantage of the strengths of both modalities. The goal of this study was the quantitative evaluation with clinical data of different MR- and PET-data-based motion correction strategies for integrated PET/MR. METHODS The PET and MR data of 20 patients w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2014