Clinical comparison of new monoclonal antibody-based nephelometric assays for free light chain kappa and lambda to polyclonal antibody-based assays and immunofixation electrophoresis.
نویسندگان
چکیده
BACKGROUND New monoclonal antibody-based assays for serum-free light chains (FLC) have become available. METHODS In a clinical study with 541 patients, the new N Latex FLC assays were compared with the Freelite FLC assays and immunofixation electrophoresis (IF). RESULTS Comparison of the different FLC kappa (κ) assays showed a slope of 0.99 with a deviation of 5.0%, rs=0.92, for FLC lambda (λ) a slope of 1.22, deviation 13.8%, rs=0.90 and for the κ/λ ratio a slope of 0.72, deviation -4.6%, rs=0.72. The concordance for the FLC κ assays was 91%, for FLC λ 85% and κ/λ ratio 95%. The clinical sensitivity and specificity of the κ/λ ratios in the study were comparable: 60% and 99% for the N Latex FLC assay and 61% and 97% for the Freelite assay. In IF-FLC positive samples, the N Latex FLC κ/λ ratio scored 20/23 (87%) samples outside the reference range and Freelite 21/23 (91%). For IF-FLC negative samples, N Latex FLC assay κ/λ ratio scored 338/350 (97%) within the reference range and Freelite scored 332/350 (95%). CONCLUSIONS The concordance scores and the clinical sensitivity and specificity of the new N Latex FLC assays and Freelite assays appeared comparable, but there are some differences in measurement of concentrations between the methods.
منابع مشابه
Clinical Comparisons of Two Free Light Chain Assays to Immunofixation Electrophoresis for Detecting Monoclonal Gammopathy
Free light chains (FLCs) are useful biomarkers for the diagnosis and monitoring of various plasma cell dyscrasias. One hundred fifty-seven samples from 120 patients for screening or monitoring of monoclonal gammopathy (MG) were included. The new N Latex FLC assays (Siemens Healthcare Diagnostics GmbH, Germany) were compared with the Freelite FLC assays (The Binding Site Ltd., UK) and the result...
متن کاملDevelopment and characterization of polyclonal antibody against human kappa light chain in rabbit
Polyclonal antibodies against kappa light chain are used to diagnose diseases producing free light chain. The kappa and lambda light chains are products of immunoglobulin synthesis and released into the circulation in minor amounts such as serum, cerebrospinal fluid, urine and synovial fluid in normal condition. The purpose of this study was the production and purification of polyclonal immunog...
متن کاملDiagnostic accuracy of monoclonal antibody based serum immunoglobulin free light chain immunoassays in myeloma cast nephropathy
UNLABELLED BACKGROUND The development of serum immunoassays for the measurement of immunoglobulin free light chains has led to a paradigm shift in the diagnosis, assessment and monitoring of patients with plasma cell dyscrasias. The impact of these immunoassays which employ polyclonal antibodies was most notable for those patients who were previously classified as non-secretory multiple myel...
متن کاملIdentification of amyloidogenic light chains requires the combination of serum-free light chain assay with immunofixation of serum and urine.
BACKGROUND The diagnosis of systemic immunoglobulin light-chain (AL) amyloidosis requires demonstration of amyloid deposits in a tissue biopsy and amyloidogenic monoclonal light chains. The optimal strategy to identify the amyloidogenic clone has not been established. We prospectively assessed the diagnostic sensitivity of the serum free light chain (FLC) kappa/lambda ratio, a commercial serum ...
متن کاملInterference of polyclonal free light chains with identification of Bence Jones proteins.
We present a case in which kappa free light chains caused difficulty in interpreting classical urinary immunoelectrophoresis, but immunofixation electrophoresis (IFE) demonstrated the presence of a lambda-Bence Jones protein. Analysis of the urine by Ouchterlony double diffusion and IFE after gel-filtration chromatography showed that the difficulty was caused by the presence of large amounts of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry and laboratory medicine
دوره 50 3 شماره
صفحات -
تاریخ انتشار 2011