Tuning the Output Impedance of RF Power Amplifiers with Frequency-Offset Cartesian Feedback

نویسندگان

  • M. G. Zanchi
  • P. Stang
  • J. M. Pauly
  • G. C. Scott
چکیده

Introduction: Coupling between coil elements of a transmit array is one of the key challenges faced by designers of MRI transmitter arrays. To address this challenge, methods and systems have been developed to change the output impedance of the RF power amplifiers driving the array coils in order to suppress inter-element coupling effects. Chu [1], for example, proposed an output-matching network to drastically lower the drain-source impedance of the power amplifier output transistor; in contrast, Kurpad [2] demonstrated the active rung concept to turn the amplifier into a very high output impedance device; similarly, Lee [3] developed a current source design to present the amplifier load with a very high impedance. All of these methods—and others—assume linear behavior of the amplifier (whereas power amplifiers can be non-linear) and have limitations such as the lessening of the power amplifier efficiency, the inability to accurately predict the exact value of the output impedance of the amplifier, or the impossibility of maintaining the latter constant over a wide range of output power. We propose the use of the Frequency-Offset Cartesian Feedback (FOCF) method and system [4] [5] to manipulate the output impedance of power amplifiers for MRI transmitter arrays predictably, inexpensively, and without hampering the efficiency of the amplifiers. Through simulations and measurements on both single amplifiers (with and without terminating circulator) and balanced amplifiers (all three shown schematically in Figure 1), we demonstrate the ability to predictably manipulate the real and imaginary parts of the series output impedance of the power amplifier from very low (~ 2 Ω) to very high (~ 500 Ω) values. Material Methods: The simplest architecture of our FOCF system includes only a directional coupler at the output of a 200 W amplifier loaded by ZL, which samples both forward (Vfwd) and reverse (Vrev) voltages, and a 0o or 180o combiner to either sum or subtract these samples before they are sent to the down-mixer of the feedback path of the FOCF transmitter driving the power amplifier. By summing forward and reverse voltage, the system controls the amplifier total output voltage (Vfwd+Vrev=Vtot) and creates a very low amplifier output impedance; by subtracting these voltages, the system controls the total output current (Vfwd-Vrev∝Itot) and creates a very high impedance It is also possible to use only the Vfwd sample as the control variable (Vfwd∝Vtot+ZO·Itot), which results in the system creating an output impedance that matches the coupler ZO impedance. Almost any other arbitrary value of output impedance can be obtained when two vector multipliers are integrated in the FOCF system,—between the directional coupler and a 0o combiner—one multiplier weighting the forward voltage sample, the other, the reverse. For each value of the complex constant K=β/α, where α and β are the coupler weighting factors of the combination α·Vfwd+β·Vrev, a unique value of the complex impedance of the power amplifier Zamp is obtained. The FOCF system with active modulators is shown in Figure 2. In addition to the FOCF transmitter, power amplifier, directional coupler, combiners, and vector multipliers, our system includes autotuning capabilities, a Medusa console [6], and the components of a load-pull setup [7], to automatically search for the stability conditions of the system, drive the FOCF transmitter, and measure the output impedance of the amplifier. The system is operated entirely via PC, using Matlab (for Medusa) and a GUI interface (for the vector multipliers). In addition to actual measurements of output impedance obtained for over 80 different values of K, we present the results of simulating the complex impedance of the power amplifier as a function of module and phase of K. Results: Figure 3 shows a plot of the very high, very low, and nearly 50 Ω amplifier impedance versus output voltage obtained using the basic FOCF system (without vector multipliers) controlling Vtot (0o combiner), Itot (180o combiner), and Vfwd, respectively. Figure 4 is a Smith chart of the 80+ values of output impedance obtained with the vector multipliers before the 0o combiner. Each of the three contours is obtained by varying the phase of K while |K| is constant and equal to 0.4, 0.6, and 0.8. These impedance values were obtained with the power amplifier loaded by ZL=56+j4 Ω. Here the maximum output power was 100 W; however, we successfully controlled the amplifier output up to its maximum rated power (200 W). Figure 5 shows the simulated module of K needed to obtain the desired real and imaginary part of Zamp, with 0≤real(Zamp)≤500 Ω and -500≤imag(Zamp)≤500 Ω. Note that |K|≤1, that is, real(Zamp)≥0 Ω, or the system will synthesize a negative resistance and become unstable. Simulations and measurements of Zamp match well for lower values of K (|K|≤0.5); at higher values, deviations from theory result from the open-loop impedance of the amplifier and the finite value of the loop gain. Conclusion: We have demonstrated a FOCF method and system to manipulate the output impedance of the RF power amplifiers for MRI transmitter arrays. The output impedance synthesized by FOCF can have any value within a large area of the Smith chart, and is stable over the power range. In principle, since Zamp is tunable, any length of coaxial cable can be used between the power amplifier and transmit coil. References: [1] X. Chu et al., MRM 61:952–961, 2009; [2] K. Kurpad et al., Concepts in Magnetic Resonance Part B 29B(2):75–83, 2006; [3] W. Lee et al., MRM 62:218–228, 2009; [4] M.G. Zanchi et al., “Frequency Offset Cartesian Feedback Control System for MRI Power Amplifier,” Proc. 17 ISMRM; [5] D. Hoult et al., JMR 171(1):64–70, 2004; [6] P. Stang et al., “Experiments in Real-Time MRI with RT-Hawk and Medusa.,” Proc. 16 ISMRM; [7] G. Scott et al., “A Load Pull/Hot S22 Analyzer for Transmit Array Amplifiers,” Proc. 17 ISMRM. Acknowledgement: This work partly supported by NIH R01 EB008108, NIH R21 EB007715, NIH R01 EB005307.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

RF Sensor Considerations for Input Predistortion Correction of Transmit Arrays

Introduction Transmit array systems offer the promise of accelerated excitation, B1 shimming, and the potential for SAR and RF safety management [1,2], while also demanding high-fidelity RF playback in a challenging multi-channel environment. Tx coil arrays are subject to mutual coupling and loading variations, while RF power amplifiers exhibit non-linearity, ill-defined output impedances, and ...

متن کامل

A Hysteretic Two-phase Supply Modulator for Envelope Tracking RF Power Amplifiers

In this paper a two-phase supply modulator suitable for envelope tracking power amplifier is presented. The designed supply modulator has the linear assisted switching architecture. Two-phase architecture is used in order to reduce the output switching ripples. The proposed architecture uses hysteretic control instead of pulse width modulation (PWM) which significantly reduces the circuit compl...

متن کامل

Design of Cartesian Feedback Rf Power Amplifier for L-band Frequency Range

A phase-alignment system is used fully integrate a power amplifier, Cartesian feedback linearization circuitry, and a phasealignment system. The phase-alignment system employs a new technique for offset-free analog multiplication that enables it to function without manual trimming. This paper demonstrates how the phase-alignment system improves the stability margins of the fully integrated Cart...

متن کامل

Electronically Tunable Impedance-Matching Networks for Intelligent RF Power Amplifiers

This paper presents the simulation and optimization design of the electronically tunable impedance-matching networks for intelligent RF power amplifiers in a cognitive radio system. Reconfigurable elements, such as varactors and RF switches are utilized to achieve the dynamic impedance matching both in the input and output matching circuit, providing coarse and fine tuning of the target impedan...

متن کامل

Concept of transformer-feedback degeneration of low-noise amplifiers

Owing to its well-known properties of possible power-noise match as well as superior noise performance, the inductively-degenerated low-noise amplifier is nowadays the most-widely used RF preamplifier topology. However, there is not much flexibility when setting the amplifier’s input impedance to match the source impedance, as for a given biasing condition, matching is achievable only for a par...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009