Egg labeling methods for gastric emptying scintigraphy are not equivalent in producing a stable solid meal.
نویسندگان
چکیده
UNLABELLED A wide range of radiolabeled test meals have been used for gastric emptying scintigraphy. The purpose of this study was to test whether (99m)Tc-sulfur colloid-labeled liquid egg white is as stable as 2 fresh whole eggs labeled with (99m)Tc-sulfur colloid and whether the cooking method is important. METHODS Whole eggs and liquid egg white were mixed with (99m)Tc-sulfur colloid and cooked by either microwaving or frying on a griddle. The cooked eggs were tested for breakdown after 2 and 4 h of incubation in gastric fluid or HCl. RESULTS Labeled liquid egg white, prepared by either method of cooking, exhibited less breakdown in gastric fluid than whole eggs. Whole eggs cooked in the microwave exhibited significantly more breakdown than liquid egg white. CONCLUSION (99m)Tc-Sulfur colloid binds better to egg whites compared with whole eggs. These results emphasize the need to evaluate the stability of new radiolabeled test meal preparations, including the method of cooking.
منابع مشابه
A valid, accurate, oYce based non-radioactive test for gastric emptying of solids
Background—Current breath tests for measurement of gastric emptying of solids are expensive, possibly inaccurate, and require cumbersome calculations. Aims—We wished to validate a simplified solid gastric emptying test using a [C]Spirulina platensis breath test for accurate results relative to scintigraphy. Subjects—Thirty healthy volunteers. Methods—We measured gastric emptying of egg containi...
متن کاملA valid, accurate, office based non-radioactive test for gastric emptying of solids.
BACKGROUND Current breath tests for measurement of gastric emptying of solids are expensive, possibly inaccurate, and require cumbersome calculations. AIMS We wished to validate a simplified solid gastric emptying test using a [(13)C]Spirulina platensis breath test for accurate results relative to scintigraphy. SUBJECTS Thirty healthy volunteers. METHODS We measured gastric emptying of eg...
متن کاملNormal Solid Gastric Emptying Values Measured by Scintigraphy Using Asian-style Meal:A Multicenter Study in Healthy Volunteers
BACKGROUND/AIMS To report gastric emptying scintigraphy, normal values should be established for a specific protocol. The aim of this study was to provide normal gastric emptying values and determine factors affecting gastric emptying using Asian rice-based meal in healthy volunteers. METHODS One hundred and ninety-two healthy volunteers were included at 7 tertiary care centers across Thailan...
متن کاملTechnical Factors in Labeling Test Meals to Determine Gastric Emptying Rate
Objective: This study investigates the behavior of two different radionuclide labels for liquid test meals and the stability of radionuclide labeling of solid meals. Methods: Technetium-99m DTPA and mTc colloid were compared as labels for liquid test meals in an in vivo investigation of gastric emptying rate. Half emptying time and retention percentages were used as parameters. Stability of sol...
متن کاملCholinergic eVects on human gastric motility
Background—Cholinergic regulation of chronotropic (frequency) and inotropic (force) aspects of antral contractility and how these impact on gastric emptying are not well delineated. Aims—To determine the eVects of cholinergic stimulation and inhibition on myoelectric, contractile, and emptying parameters of gastric motility. Methods—Ten normal subjects underwent three studies each, using simult...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 48 11 شماره
صفحات -
تاریخ انتشار 2007