Radioimmunoassay of serum ferritin.
نویسندگان
چکیده
Purified human spleen ferritin was labelled with 125I. On Sepharose 6-B gel filtration four species of labelled products were separated: a component with a higher molecular weight than ferritin; a component which is eluted in the same volume as unlabelled ferritin; and two labelled compounds with molecular weights lower than ferritin. When these labelled materials were used in a double antibody radioimmunoassay, the high molecular weight fraction showed variable and high non-specific binding and was poorly displaced by unlabelled ferritin; the fraction behaving like true ferritin gave good standard curves and showed non-specific binding of less than 1%. The remaining two components showed poor binding to rabbit antiferritin. Using labelled material from the second fraction, a double antibody radioimmunoassay capable of measuring 2 microgram ferritin protein/litre of serum was developed. Inter- and intra-assay variation was between 3% and 8% over a concentration range of 0 to 250 microgram ferritin protein/litre. Good agreement between serum ferritin levels assayed by the present method and by an immunoradiometric method was obtained. Labelled ferritin was stable for at least six weeks. The simplicity of the methodology makes it possible to assay serum ferritin in large batches.
منابع مشابه
Enzyme immunoassay for human ferritin.
We describe an enzyme immunoassay with use of beta-D-galactosidase for quantitation of ferritin in human serum. The minimum detectable ferritin concentration is 0.25 microgram/L of serum, which is comparable to results obtained by radioimmunoassay. The correlation coefficient between values determined by enzyme immunoassay and radioimmunoassay was 0.95 (n - 1 = 85, p less than 0.001).
متن کاملImplications of using different tissue ferritins as antigens for ferritin in serum: four radioimmunoassay kits compared.
We compared three serum ferritin radioimmunoassay kits and one noncommercial RIA for ferritin quantitation, with regression analysis of results for sera from 35 ostensibly healthy subjects. There was a good correlation (p less than 0.001) between these various RIAs, but the slope of the regression line varied widely, most probably because of lack of standardization of the serum ferritin assay. ...
متن کاملSolid-phase enzyme immunoassay for serum ferritin.
We describe a solid-phase enzyme immunoassay for ferritin in human serum, with use of a horseradish peroxidase-labeled antibody and a highly sensitive chromogen, 2,2'-azino-di(3-ethyl-benzthiazoline-6-sulfonate). The assay requires only 10 microL of serum per assay, relatively less time and labor than other assys for ferritin, and as little as 10 pg of ferritin can be measured. We believe this ...
متن کاملSerum ferritin levels in apparently healthy subjects.
Serum ferritin levels were estimated in 78 normal subjects (46 males and 37 females) using radioimmunoassay techniques. The mean serum ferritin level in normal men was 83 ng/ml (range 7.4 190.0 ng/ml), compared with 43 ng/ml (range 5.1 — 104 ng/mI) in normal women. The difference in the mean ferritin level between the two sexes was significant. A concentration below 10 ng/mI was associated with...
متن کاملThe measurement and interpretation of serum ferritin.
Determination of serum ferritin is an important means of assessing body iron stores. Trace amounts of ferritin normally present in serum are detectable by sensitive radioimmunoassay techniques or an enzyme immunoassay procedure. Ferritin normally accounts for no more than a very small fraction of the total iron in serum, but generally maintains a stable concentration that is proportional to the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 31 9 شماره
صفحات -
تاریخ انتشار 1978