Fast joint design method for parallel excitation radiofrequency pulse and gradient waveforms considering off-resonance.

نویسندگان

  • Daehyun Yoon
  • Jeffrey A Fessler
  • Anna C Gilbert
  • Douglas C Noll
چکیده

A fast parallel excitation pulse design algorithm to select and to order phase-encoding (PE) locations (also known as "spokes") of an Echo-Volumar excitation k-space trajectory considering B(0) field inhomogeneity is presented. Recently, other groups have conducted research to choose optimal PE locations, but the potential benefit of considering B(0) field inhomogeneity during PE location selection or their ordering has not been fully investigated. This article introduces a novel fast greedy algorithm to determine PE locations and their order that takes into account the off-resonance effects. Computer simulations of the proposed algorithm for B(1) field inhomogeneity correction demonstrate that it not only improves excitation accuracy but also provides an effective ordering of the PE locations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

VERSE-guided numerical RF pulse design: a fast method for peak RF power control.

In parallel excitation, the computational speed of numerical radiofrequency (RF) pulse design methods is critical when subject dependencies and system nonidealities need to be incorporated on-the-fly. One important concern with optimization-based methods is high peak RF power exceeding hardware or safety limits. Hence, online controllability of the peak RF power is essential. Variable-rate sele...

متن کامل

Small-tip fast recovery imaging using non-slice-selective tailored tip-up pulses and radiofrequency-spoiling.

Small-tip fast recovery (STFR) imaging is a new steady-state imaging sequence that is a potential alternative to balanced steady-state free precession. Under ideal imaging conditions, STFR may provide comparable signal-to-noise ratio and image contrast as balanced steady-state free precession, but without signal variations due to resonance offset. STFR relies on a tailored "tip-up," or "fast re...

متن کامل

VERSE‐guided parallel RF excitations using dynamic field correction

In parallel RF pulse design, peak RF magnitudes and specific absorption rate levels are critical concerns in the hardware and safety limits. The variable rate selective excitation (VERSE) method is an efficient technique to limit the peak RF power by applying a local-only RF and gradient waveform reshaping while retaining the on-resonance profile. The accuracy of the excitation performed by the...

متن کامل

Specific absorption rate reduction using nonlinear gradient fields.

The specific absorption rate is used as one of the main safety parameters in magnetic resonance imaging. The performance of imaging sequences is frequently hampered by the limitations imposed on the specific absorption rate that increase in severity at higher field strengths. The most well-known approach to reducing the specific absorption rate is presumably the variable rate selective excitati...

متن کامل

Joint design of large-tip-angle parallel RF pulses and blipped gradient trajectories.

PURPOSE To design multichannel large-tip-angle kT-points and spokes radiofrequency (RF) pulses and gradient waveforms for transmit field inhomogeneity compensation in high field magnetic resonance imaging. THEORY AND METHODS An algorithm to design RF subpulse weights and gradient blip areas is proposed to minimize a magnitude least-squares cost function that measures the difference between re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 68 1  شماره 

صفحات  -

تاریخ انتشار 2012