In vivo dosimetry with diodes in rectal cancer patients
نویسنده
چکیده
Background. Success of radiotherapy relies on accurate dose delivery. In vivo dosimetry improves control of treatment quality. Patients and methods. In vivo dosimetry with commercial diodes was performed in 209 rectal cancer patients treated with four-field box technique. The diodes measured either entrance or exit dose in each treatment field. The results were compared to the planned values and the dose delivered to the isocenter was calculated. Tolerance levels were set to 5% for entrance dose and 8% for exit dose. Results. 421 entrance dose and 415 exit dose measurements were performed. The average difference from expected values was 0.9% for entrance dose (SD 2.1%) and -0.5% for exit dose (SD 3.3%). In 209 patients, the average absorbed dose in the isocenter differed from the planned values by 0.2% (SD 1.4%). Measurement results exceeded the tolerance levels in two patients. Conclusion. Smaller standard deviation of absorbed dose to the isocenter (1.4%), compared to those of entrance (2.1%) and exit dose measurements (3.3%), confirms a correlation between the entrance and exit dose deviations of pairs of opposed fields. The fact that during this study in vivo dosimetry exposed two cases of potentially inaccurate treatments proves its necessity.
منابع مشابه
In Vivo Dosimetry Using a Flat Surface Sun Nuclear Corporation Diode in 60co Beams for Some Radiotherapy Treatments in Ghana
Introduction: One of the useful standard quality assurance techniques in radiation therapy is monitoring entrance doses in in-vivo dosimetry. An overall tolerance limit of 5% of the absorbed radiation dose has been recommended by the International Commission of Radiological Units. The implementation of an in vivo dosimet...
متن کاملRectal and Bladder Dose Measurements in the Intracavitary Applications of Cervical Cancer Treatment with HDR Afterloading System: Comparison of TPS Data with MOSFET Detector
Background: Intracavitary brachytherapy plays a major role in management of cervical carcinoma. Assessment of dose received by OAR’s therefore becomes crucial for the estimation of radiation toxicities in HDR brachytherapy. Objective: Purpose of this study is to evaluate the role of in vivo dosimetry in HDR brachytherapy and to compare actual doses delivered to OAR’ s with those calculate...
متن کاملVerification of the Accuracy of the Delivered Dose in Brain Tumors by in Vivo Dosimetry Using Diode Detectors
Introduction: During radiotherapy, high accuracy in the dose delivery is required because there is a strong relationship between the absorbed dose, local tumor control and particularly the normal tissue damage. In many institutions, in vivo dosimetry using diodes is performed to check the actual dose delivered. In general, the uncertainty in the dose delivered should fall within ± 5% of the...
متن کاملVerification of the Accuracy of the Delivered Dose in Pelvic and Breast Cancer Radiotherapy by in-vivo Semi-Conductor Dosimetry
Introduction: Delivering maximum dose to tumor and minimum dose to normal tissues is the most important goal in radiotherapy. According to ICRU, the maximum acceptable uncertainty in the delivered dose compared to the prescribed dose should be lower than 5%, and this is because of the relationship between absorbed dose, tumor control and normal tissue damage. Absorbed dose accuracy is investiga...
متن کاملAchievable accuracy in brain tumors by in vivo dosimetry with diode detectors
ABSTRACT Background: In vivo measurements of applied dose during radiotherapy treatment, is important to ensure accurate dose delivery to patients. Uncertainty in dose delivery should fall within ±5% of the prescribed dose as recommended by ICRU. Assessment of dose for radiotherapy applications performed with various types of detectors. In this study, semiconductor diodes were used which have s...