Reproducibility of near-infrared spectroscopy parameters measured during brachial artery occlusion and reactive hyperemia in healthy men.
نویسندگان
چکیده
Near-infrared spectroscopy (NIRS) is a noninvasive technique evaluating microvascular function. The aim of this study was to assess the reproducibility of NIRS parameters during reactive hyperemia induced by a 5 min brachial artery occlusion. Twenty-four healthy young males (mean 34 ± 8 years old) had two microvascular function evaluations by NIRS over a 7 to 30-day period (mean 16 ± 10 days). Intra-subject and inter-observer reproducibility were evaluated with intraclass correlation coefficient (ICC), coefficient of variation (CV), and standard error of measurement (SEM%) for every parameter. Mean NIRS parameters did not differ between both evaluations. Reproducibility was greatest for muscle oxygen consumption (ICC: 0.84; CV: 6.51%; SEM: 7.11%), time to basal O(2)Hb (ICC: 0.63, CV: 20.04%, SEM 27.22%), time to maximal O(2)Hb (ICC: 0.71; CV: 15.61%; SEM: 19.27%), peak of O(2)Hb (ICC: 0.63, CV: 6.68%, SEM 8.53%), time to maximal tHb (ICC: 0.73, CV: 19,61%, SEM 24.56%) and area under the O(2)Hb and tHb curves (ICC: 0.68, CV: 16.15%, SEM 22.93% and ICC: 0.62, CV: 18.59%, SEM 26.64%, respectively). Moreover, inter-observer reproducibility ranged from excellent to perfect (ICC from 0.85 to 1.00) for every parameter. NIRS parameters during reactive hyperemia are highly reproducible which enables their repeated measurement to study microvascular function in healthy subjects.
منابع مشابه
Postocclusive reactive hyperemia in healthy volunteers and patients with peripheral vascular disease measured by three noninvasive methods.
Postocclusive reactive hyperemia (PORH) was evaluated in three healthy volunteers and in three patients with different etiologies and suffering from peripheral arterial occlusive disease (PAOD). Three noninvasive methods were used: transcutaneous oximetry (TcPO2), near-infrared spectroscopy (NIRS), and laser Doppler flowmetry (LDF). Changes in perfusion and oxygenation of tissue were measured o...
متن کاملNormalization of flow-mediated dilation to shear stress area under the curve eliminates the impact of variable hyperemic stimulus
BACKGROUND Normalization of brachial artery flow-mediated dilation (FMD) to individual shear stress area under the curve (peak FMD:SSAUC ratio) has recently been proposed as an approach to control for the large inter-subject variability in reactive hyperemia-induced shear stress; however, the adoption of this approach among researchers has been slow. The present study was designed to further ex...
متن کاملPeripheral muscle microcirculatory alterations in patients with pulmonary arterial hypertension: a pilot study.
BACKGROUND Pulmonary microcirculation abnormalities are the main determinants of pulmonary arterial hypertension (PAH) pathophysiology. We hypothesized that PAH patients have peripheral tissue microcirculation alterations that might benefit from hyperoxic breathing. We evaluated peripheral muscle microcirculation with near-infrared spectroscopy, before and after hyperoxic breathing. METHODS E...
متن کاملReproducibility of parameters of postocclusive reactive hyperemia measured by diffuse optical tomography.
The application of near-infrared spectroscopy (NIRS) to assess microvascular function has shown promising results. An important limitation when using a single source-detector pair, however, is the lack of depth sensitivity. Diffuse optical tomography (DOT) overcomes this limitation using an array of sources and detectors that allow the reconstruction of volumetric hemodynamic changes. This stud...
متن کامل500 ml of blood loss does not decrease non-invasive tissue oxygen saturation (StO2) as measured by near infrared spectroscopy - A hypothesis generating pilot study in healthy adult women
BACKGROUND The goal when resuscitating trauma patients is to achieve adequate tissue perfusion. One parameter of tissue perfusion is tissue oxygen saturation (StO2), as measured by near infrared spectroscopy. Using a commercially available device, we investigated whether clinically relevant blood loss of 500 ml in healthy volunteers can be detected by changes in StO2 after a standardized ischem...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 17 7 شماره
صفحات -
تاریخ انتشار 2012