Three-dimensional imaging and morphometric analysis of alveolar tissue from microfocal X-ray-computed tomography.
نویسندگان
چکیده
We evaluated microfocal X-ray-computed tomography (micro-CT) as a method to visualize lung architecture two and three dimensionally and to obtain morphometric data. Inflated porcine lungs were fixed by formaldehyde ventilation. Tissue samples (8-mm diameter, 10-mm height) were stained with osmium tetroxide, and 400 projection images (1,024 x 1,024 pixel) were obtained. Continuous isometric micro-CT scans (voxel size 9 microm) were acquired to reconstruct two- and three-dimensional images. Tissue samples were sectioned (8-microm thickness) for histological analysis. Alveolar surface density and mean linear intercept were assessed by stereology-based morphometry in micro-CT scans and corresponding histological sections. Furthermore, stereology-based morphometry was compared with morphometric semi-automated micro-CT analysis within the same micro-CT scan. Agreement of methods was assessed by regression and Bland-Altman analysis. Comparing histology with micro-CT, alveolar surface densities (35.4 +/- 2.4 vs. 33.4 +/- 1.9/mm, P < 0.05) showed a correlation (r = 0.72; P = 0.018) with an agreement of 2 +/- 1.6/mm; the mean linear intercept (135.7 +/- 14.5 vs. 135.8 +/- 15 microm) correlated well (r = 0.97; P < 0.0001) with an agreement of -0.1 +/- 3.4 microm. Semi-automated micro-CT analysis resulted in smaller alveolar surface densities (33.4 +/- 1.9 vs. 30.5 +/- 1/mm; P < 0.01) with a correlation (r = 0.70; P = 0.023) and agreement of 2.9 +/- 1.4/mm. Non-destructive micro-CT scanning offers the advantage to visualize the spatial tissue architecture of small lung samples two and three dimensionally.
منابع مشابه
Innovative Methodology Three-dimensional imaging and morphometric analysis of alveolar tissue from microfocal X-ray-computed tomography
Litzlbauer, Horst Detlef, Christoph Neuhaeuser, Alexander Moell, Susanne Greschus, Andreas Breithecker, Folker Ernst Franke, Wolfgang Kummer, and Wigbert Stephan Rau. Threedimensional imaging and morphometric analysis of alveolar tissue from microfocal X-ray-computed tomography. Am J Physiol Lung Cell Mol Physiol 291: L535–L545, 2006. First published May 5, 2006; doi:10.1152/ajplung.00088.2005....
متن کاملThree-dimensional visualization and morphometry of small airways from microfocal X-ray computed tomography.
Physiological morphometry is a critical factor in the flow dynamics in small airways. In this study, we visualized and analyzed the three-dimensional structure of the small airways without dehydration and fixation. We developed a two-step method to visualize small airways in detail by staining the lung tissue with a radiopaque solution and then visualizing the tissue with a cone-beam microfocal...
متن کاملSpatial Relationship between Mandibular Third Molars and Inferior Alveolar Nerve using a Volume Rendering Software
Precise localization of the third molars in relation to the inferior alveolar nerve canal is critical from a clinical point of view and strongly affects the surgical treatment outcome. Recently, by using three-dimensional modeling software, the relationship of third molar root apices and inferior alveolar nerve canal can be better understood. In this study, the spatial relationship of two surgi...
متن کاملAn iterative method to estimate x-ray attenuation coefficients in computed tomography
Introduction: The basis of image formation in Computed Tomography (CT) lies in the x-ray linear attenuation coefficient of the scanned material. Compton scattering and photoelectric effect are the dominant interactions of the x-ray photons with the subject, in the range of diagnostic radiology. These two coefficients are important in tissue characterization by Dual-Energy CT (D...
متن کاملPulmonary arterial morphometry from microfocal X-ray computed tomography.
The objective of this study was to develop an X-ray computed tomographic method for pulmonary arterial morphometry. The lungs were removed from a rat, and the pulmonary arterial tree was filled with perfluorooctyl bromide to enhance X-ray absorbance. At each of four pulmonary arterial pressures (30, 21, 12, and 5.4 mmHg), the lungs were rotated within the cone of the X-ray beam that was project...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Lung cellular and molecular physiology
دوره 291 3 شماره
صفحات -
تاریخ انتشار 2006