Left ventricular systolic unloading and augmentation of intracoronary pressure and Doppler flow during enhanced external counterpulsation.
نویسندگان
چکیده
BACKGROUND Enhanced external counterpulsation (EECP) is a noninvasive, pneumatic technique that provides beneficial effects for patients with chronic, symptomatic angina pectoris. However, the physiological effects of EECP have not been studied directly. We examined intracoronary and left ventricular hemodynamics in the cardiac catheterization laboratory during EECP. METHODS AND RESULTS Ten patients referred for diagnostic evaluation underwent left heart catheterization and coronary angiography from the radial artery. At baseline and then during EECP, central aortic pressure, intracoronary pressure, and intracoronary Doppler flow velocity were measured using a coronary catheter, a sensor-tipped high-fidelity pressure guidewire, and a Doppler flow guidewire, respectively. Similar to changes in aortic pressure, EECP resulted in a dramatic increase in diastolic (71+/-10 mm Hg at baseline to 137+/-21 mm Hg during EECP; +93%; P<0.0001) and mean intracoronary pressures (88+/-9 to 102+/-16 mm Hg; +16%; P=0.006) with a decrease in systolic pressure (116+/-20 to 99+/-26 mm Hg; -15%; P=0.002). The intracoronary Doppler measure of average peak velocity increased from 11+/-5 cm/s at baseline to 23+/-5 cm/s during EECP (+109%; P=0.001). The TIMI frame count, a quantitative angiographic measure of coronary flow, showed a 28% increase in coronary flow during EECP compared with baseline (P=0.001). CONCLUSIONS EECP unequivocally and significantly increases diastolic and mean pressures and reduces systolic pressure in the central aorta and the coronary artery. Coronary artery flow, determined by both Doppler and angiographic techniques, is increased during EECP. The combined effects of systolic unloading and increased coronary perfusion pressure provide evidence that EECP may serve as a potential mechanical assist device.
منابع مشابه
Axial-Flow, Transvalvular Left Ventricular Assist Device
Background. It has been suggested that left ventricular unloading at the time of reperfusion provides superior infarct salvage over reperfusion alone. The purpose of this study was to show that the Hemopump transvalvular axial-flow left ventricular assist device provides superior left ventricular unloading, ischemic zone collateral blood flow, and infarct size reduction compared with intra-aort...
متن کاملCanine Infarction Model
Background. It has been suggested that left ventricular unloading at the time of reperfusion provides superior infarct salvage over reperfusion alone. The purpose of this study was to show that the Hemopump transvalvular axial-flow left ventricular assist device provides superior left ventricular unloading, ischemic zone collateral blood flow, and infarct size reduction compared with intra-aort...
متن کاملInvasive left ventricular energetics during enhanced external counterpulsation.
Enhanced external counterpulsation (EECP) is a noninvasive technique that provides beneficial effects for patients with chronic, symptomatic angina pectoris. However, the direct left ventricular effects of EECP have not been studied invasively. We examined invasive right atrial pressure and left ventricular hemodynamics during EECP. Ten patients referred for diagnostic evaluation underwent left...
متن کاملLEFT VENTRICULAR DIASTOLIC ABNORMALITIES IN β-THALASSEMIA MAJOR WITH NORMAL SYSTOLIC FUNCTION
In order to identify left ventricular diastolic function in patients with betathalassemia major and normal systolic function by noninvasive M-mode and Doppler echocardiography, an analytic study was designed in a university hospital in Sari. We have studied 44 patients (23 men and 21 women), mean age 15.48±2.16 (range 12 to 20) and 43 age and sex matched control subjects. Peak flow velocit...
متن کاملClinical Practice of EECP in Non-Cardiac Disease in China
Introduction Enhanced external counterpulsation is a technique using a set of cuffs that are wrapped around the lower part of the body. During treatment, pressure is sequentially applied via the cuffs to the lower extremities of the patient synchronized by cardiac cycle. At early diastole, pressure is applied sequentially from the lower legs to the lower and upper thighs, to propel blood back t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 106 10 شماره
صفحات -
تاریخ انتشار 2002