A wavelet-based approximation of surface coil sensitivity profiles for correction of image intensity inhomogeneity and parallel imaging reconstruction.

نویسندگان

  • Fa-Hsuan Lin
  • Ying-Jui Chen
  • John W Belliveau
  • Lawrence L Wald
چکیده

We evaluate a wavelet-based algorithm to estimate the coil sensitivity modulation from surface coils. This information is used to improve the image homogeneity of magnetic resonance imaging when a surface coil is used for reception, and to increase image encoding speed by reconstructing images from under-sampled (aliased) acquisitions using parallel magnetic resonance imaging (MRI) methods for higher spatiotemporal image resolutions. The proposed algorithm estimates the spatial sensitivity profile of surface coils from the original anatomical images directly without using the body coil for additional reference scans or using coil position markers for electromagnetic model-based calculations. No prior knowledge about the anatomy is required for the application of the algorithm. The estimation of the coil sensitivity profile based on the wavelet transform of the original image data was found to provide a robust method for removing the slowly varying spatial sensitivity pattern of the surface coil image and recovering full FOV images from two-fold acceleration in 8-channel parallel MRI. The results, using bi-orthogonal Daubechies 97 wavelets and other members in this family, are evaluated for T1-weighted and T2-weighted brain imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coil Sensitivity Estimation for Optimal SNR Reconstruction and Intensity Inhomogeneity Correction in Phased Array MR Imaging

Magnetic resonance (MR) images can be acquired by multiple receiver coil systems to improve signal-to-noise ratio (SNR) and to decrease acquisition time. The optimal SNR images can be reconstructed from the coil data when the coil sensitivities are known. In typical MR imaging studies, the information about coil sensitivity profiles is not available. In such cases the sum-of-squares (SoS) recon...

متن کامل

Projection-based estimation and nonuniformity correction of sensitivity profiles in phased-array surface coils.

PURPOSE To develop a novel approach for calculating the accurate sensitivity profiles of phased-array coils, resulting in correction of nonuniform intensity in parallel MRI. MATERIALS AND METHODS The proposed intensity-correction method estimates the accurate sensitivity profile of each channel of the phased-array coil. The sensitivity profile is estimated by fitting a nonlinear curve to ever...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Inherent insensitivity to B1 field inhomogeneity using regularized nonlinear inversion reconstruction

INTRODUCTION Signal intensity variation that arises from inhomogeneous transmit and receive fields not only complicates the qualitative appearance of MR images but also presents the major source of error in quantitative MRI/S. Many current approaches address this problem by mapping the transmit field [1] and assuming the same transmit and receive field patterns during compensation [2]. However,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Human brain mapping

دوره 19 2  شماره 

صفحات  -

تاریخ انتشار 2003