Background and purpose - Total knee replacement (TKR) in younger patients using cemented components has shown inferior results, mainly due to aseptic loosening. Excellent clinical results have been reported with components made of trabecular metal (TM). In a previous report, we have shown stabilization of the TM tibial implants for up to 5 years. In this study, we compared the clinical and RSA results of these uncemented implants with those of cemented implants. Patients and methods - 41 patients (47 knees) aged ≤ 60 years underwent TKR. 22 patients (26 knees) received an uncemented monoblock cruciate-retaining (CR) tibial component (TM) and 19 patients (21 knees) received a cemented NexGen Option CR tibial component. Follow-up examination was done at 10 years, and 16 patients (19 knees) with TM tibial components and 17 patients (18 knees) with cemented tibial components remained for analysis. Results - 1 of 19 TM implants was revised for infection, 2 of 18 cemented components were revised for knee instability, and no revisions were done for loosening. Both types of tibial components migrated in the first 3 months, the TM group to a greater extent than the cemented group. After 3 months, both groups were stable during the next 10 years. Interpretation - The patterns of migration for uncemented TM implants and cemented tibial implants over the first 10 years indicate that they have a good long-term prognosis regarding fixation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trabecular metal tibia still stable at 5 years

BACKGROUND AND PURPOSE Clinical results of total knee replacement (TKR) are inferior in younger patients, mainly due to aseptic loosening. Coating of components with trabecular metal (TM) is a new way of enhancing fixation to bone. We have previously reported stabilization of TM tibial components at 2 years. We now report the 5-year follow-up of these patients, including RSA of their TM tibial ...

متن کامل

A trabecular metal tibial component in total knee replacement in patients younger than 60 years: a two-year radiostereophotogrammetric analysis.

We compared the performance of uncemented trabecular metal tibial components in total knee replacement with that of cemented tibial components in patients younger than 60 years over two years using radiostereophotogrammetric analysis (RSA). A total of 22 consecutive patients (mean age 53 years, 33 to 59, 26 knees) received an uncemented NexGen trabecular metal cruciate-retaining monobloc tibial...

متن کامل

Continued stabilization of trabecular metal tibial monoblock total knee arthroplasty components at 5 years—measured with radiostereometric analysis

BACKGROUND AND PURPOSE The trabecular metal tibial monoblock component (TM) is a relatively new option available for total knee arthroplasty. We have previously reported a large degree of early migration of the trabecular metal component in a subset of patients. These implants all appeared to stabilize at 2 years. We now present 5-year RSA results of the TM and compare them with those of the Ne...

متن کامل

Total knee arthroplasty Aspects on improved fixation in the younger patient Av

Mobile bearings do not improve fixation in cemented total knee arthroplasty. Trabecular metal tibial component in patients younger than 60 years. A prospective RSA study. Cemented versus uncemented fixation of the femoral component of the NexGen CR total knee replacement in patients younger than 60 years. A randomized RSA study. Submitted 2008.

متن کامل

Superior fixation of pegged trabecular metal over screw-fixed pegged porous titanium fiber mesh

BACKGROUND AND PURPOSE Lasting stability of cementless implants depends on osseointegration into the implant surface, and long-term implant fixation can be predicted using radiostereometric analysis (RSA) with short-term follow-up. We hypothesized that there would be improved fixation of high-porosity trabecular metal (TM) tibial components compared to low-porosity titanium pegged porous fiber-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 87  شماره 

صفحات  -

تاریخ انتشار 2016