Evaluation of Quadrox-i adult hollow fiber oxygenator with integrated arterial filter.
نویسندگان
چکیده
Gaseous microemboli (GME) remain a challenge for cardiopulmonary bypass procedures in adult as well as pediatric cardiac surgery patients. The present study tested the effectiveness of a new adult membrane oxygenator in models both with and without an integrated arterial filter to evaluate GME trapping capability and determine membrane pressure drops at various flow rates and temperatures. The experimental circuit included a RotaFlow centrifugal blood pump, Quadrox-i (n = 8) or Quadrox (n = 8) adult microporous membrane oxygenator, and Sorin adult tubing package. A Sorin Cardiovascular VVR 4000i venous reservoir served as pseudo-patient. The circuit was primed with 900 mL heparinized human red blood cells and 300 mL Lactated Ringer's solution. The final hematocrit was 36%. Tests were performed at different flow rates (4 L/min, 5 L/min, and 6 L/min) and temperatures (35 degrees and 30 degrees). Five mL of bolus air was injected into the venous line over 15 seconds using a syringe connected to a 3/8 x 1/2 luer connector. The Quadrox-i adult microporous membrane oxygenator with integrated arterial filter had a similar pressure drop at 4 L/min and 35 degrees C compared with Quadrox membrane oxygenator whereas it had higher pressure drops at 5 L/min and 6 L/min (p < .001). Quadrox-i adult microporous membrane oxygenator reduced the total emboli count and total emboli volume delivered to the pseudo-patient at all flow rates (p < .001).The emboli handling of Quadrox-i adult microporous membrane oxygenator was not affected by flow rate and temperature. Compared with the traditional Quadrox oxygenator, Quadrox-i adult microporous membrane oxygenator with integrated arterial filter and Softline coating has improved GME handling capacity.
منابع مشابه
Effect of Normobaric versus Hypobaric Oxygenation on Gaseous Microemboli Removal in a Diffusion Membrane Oxygenator: An In Vitro Comparison.
Gaseous microemboli (GME) are an abnormal physiological occurrence during cardiopulmonary bypass and extracorporeal membrane oxygenation (ECMO). Several studies have correlated negative sequelae with exposure to increased amounts of GME. Hypobaric oxygenation is effective at eliminating GME in hollow-fiber microporous membrane oxygenators. However, hollow-fiber diffusion membrane oxygenators, w...
متن کاملClinical evaluation of the Sorin Synthesis oxygenator with integrated arterial filter.
The use of arterial line filters has long been a standard of practice in the field of cardiopulmonary bypass. Sorin Biomedica has designed an adult hollow-fiber oxygenator that not only incorporates their Mimesys biomimicry coating technology but also has a 40-micron arterial filter as an integrated component of this unique membrane oxygenator. We did a prospective, randomized clinical trial of...
متن کاملA clinical evaluation of the Terumo Capiox SX18R hollow fiber oxygenator.
The Terumo Capiox SX18R is a commercially available, low prime, reverse phase, hollow fiber membrane oxygenator. The oxygenator consists of a 1.8 m2 microporous polypropylene hollow fiber bundle, a 2200 cm2 tubular stainless steel heat exchanger, and an open hard shell venous reservoir with integral cardiotomy filter. The Terumo Capiox SX18R oxygenator was evaluated to determine its clinical ox...
متن کاملClinical evaluation of the Terumo Capiox FX05 hollow fiber oxygenator with integrated arterial line filter.
Perfusion techniques and equipment in pediatric open heart surgery have continued to focus on decreasing prime volumes and lowering surface areas of the cardiopulmonary bypass circuit. While this has improved drastically over the last 20 years, greater demand is being placed on the perfusionist to reduce the deleterious effects of bypass without compromising safety or efficiency. Specifically, ...
متن کاملIn vitro drug adsorption and plasma free hemoglobin levels associated with hollow fiber oxygenators in the extracorporeal life support (ECLS) circuit.
The purpose of this study was to identify the percentage of fentanyl or morphine sulfate lost from adhesion to either the polyvinylchloride (PVC) tubing or the surface of two different hollow fiber oxygenators used in current extracorporeal life support circuits and to identify any difference in the plasma free hemoglobin (PFH) levels generated when using these oxygenator and/or drug combinatio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 42 3 شماره
صفحات -
تاریخ انتشار 2010