False-negative results of breast core needle biopsies – retrospective analysis of 988 biopsies

نویسندگان

  • Marek Boba
  • Urszula Kołtun
  • Barbara Bobek-Billewicz
  • Ewa Chmielik
  • Bartosz Eksner
  • Tomasz Olejnik
چکیده

BACKGROUND Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. MATERIAL/METHODS 988 core needle breast biopsies were performed at the Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. RESULTS Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. CONCLUSIONS Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی نمونه‌های آسیب‌شناسی حاصل از بیوپسی سوزنی با هدایت سی‌تی‌اسکن در ضایعات قفسه سینه بیماران مراجعه‌کننده به بخش پاتولوژی بیمارستان شهید صدوقی یزد

Introduction: Despite the popularity of needle biopsy for obtaining tissue samples in several solid organs, its use in thoracic lesions has been very restricted in some hospitals. This study intended to investigate the CT-Guided transthoracic core needle biopsy specimens in Yazd Shahid Sadoughi hospital during 2001- 2010. Methods: This is a retrospective cross- sectional study conducted on pat...

متن کامل

PERCUTANEOUS TRANSTHORACIC BIOPSY USING TRU-CUT NEEDLE

Biopsies of thoracic lesions guidance. 22 of the 1 12 lesions were mediastinal and 83 were pleuroparenchymal. A large-bore 14-gauge Tru-cut needle was used in all patients. Adequate specimens for histologic examination were obtained in 98%. The overall accuracy was 91 % with 9% false negative and no false positive diagnoses. Despite the large size of the needle, the total number of complic...

متن کامل

Raman spectroscopy: a real-time tool for identifying microcalcifications during stereotactic breast core needle biopsies

Microcalcifications are an early mammographic sign of breast cancer and a target for stereotactic breast needle biopsy. We present here a Raman spectroscopic tool for detecting microcalcifications in breast tissue based on their chemical composition. We collected ex vivo Raman spectra from 159 tissue sites in fresh stereotactic breast needle biopsies from 33 patients, including 54 normal sites,...

متن کامل

Changing attitudes toward needle biopsies of breast cancer in Shanghai: experience and current status over the past 8 years

Diagnostic patterns in breast cancer have greatly changed over the past few decades, and core needle biopsy (CNB) has become a reliable procedure for detecting breast cancer without invasive surgery. To estimate the changing diagnostic patterns of breast cancer in urban Shanghai, 11,947 women with breast lesions detected by preoperative needle biopsy between January 1995 and December 2012 were ...

متن کامل

Histopathologic Review of Previously Negative Prostatic Core Needle Biopsies Following a New Diagnosis of Adenocarcinoma of the Prostate by Core Needle Biopsies: Implications for Quality Assurance Programs

Programs for quality assurance are increasingly important in surgical pathology. Many quality assurance (QA) techniques for surgical pathology were adopted from procedures introduced in cytopathology. Surgical pathology specimens have diminished in size such that the majority of diagnostic biopsies of prostatic lesions are now core needle biopsies. These specimens raise issues similar to those ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 76  شماره 

صفحات  -

تاریخ انتشار 2011