Effect of sputum induction on arterial oxygen saturation and spirometry in HIV-infected patients.
نویسندگان
چکیده
We wanted to study the effect of sputum induction on forced expiratory volume in one second (FEV1) and on oxygen saturation in normal controls, asymptomatic human immunodeficiency virus (HIV)-seropositive individuals, and HIV-seropositive patients under investigation for suspected Pneumocystis carinii pneumonia (PCP). Over a five month period, sputum induction with ultrasonically nebulized 3% saline was performed on 110 HIV-seropositive patients with suspected PCP, 10 asymptomatic HIV-seropositive patients, and 15 normal controls. Oxygen saturation (peak, trough and change in oxygen saturation (delta O2)) was measured throughout the procedure using pulse oximetry, and these results compared with the chest radiograph and the final pulmonary diagnosis. In addition, the effect of sputum induction on FEV1 was measured in the 15 control subjects and 10 asymptomatic HIV-seropositive patients. Compared with bronchoalveolar lavage, sputum induction had a diagnostic sensitivity for PCP of 76%. Chest radiography was 79% sensitive, and had specificity of 83%. Patients with PCP had lower peak and trough oxygen saturation values compared with the non-PCP group (mean peak 95 vs 97%; mean trough 88 vs 91%), and greater falls in O2 saturation during the procedure (mean delta O2 7.6 vs 5.5%). One subject desaturated to 76%, requiring supplemental oxygen. Sputum induction caused significant but temporary falls in FEV1 both in control and HIV-seropositive groups (mean maximum fall in FEV1 10.4 vs 12.5%). We conclude that although sputum induction causes significant falls in oxygen saturation and FEV1, it remains sensitive and safe, and provides a useful alternative to bronchoscopy for the diagnosis of PCP.
منابع مشابه
Arterial desaturation in HIV positive patients undergoing sputum induction.
Arterial oxygen saturation (SaO2) was monitored continuously during and immediately after sputum induction in 41 HIV positive patients with respiratory symptoms and in 20 symptomless medical and nursing staff, who acted as control subjects. Arterial oxygen desaturation (defined as SaO2 less than or equal to 92%) occurred during sputum induction and persisted for up to 20 minutes after the end o...
متن کاملComparing the Effect of Simple Filtration Hemodialysis and Ultrafiltration Hemodialysis on Arterial Oxygen Saturation and Blood Pressure in Chronic Dialysis
Background and purpose: Hypoxemia and hypotension are important complications of hemodialysis in patients with chronic renal failure that are linked to several factors, including the type of filters used. The aim of this study was to compare the effect of simple filtration hemodialysis and ultrafiltration hemodialysis on blood pressure and blood arterial oxygen level. Materials and methods: In...
متن کاملThe Effect of Controlled Breathing Exercises on Anxiety and Arterial Oxygen Saturation in Chronic Obstructive Pulmonary Disease
Introduction: Anxiety is one of the common symptoms and complications in patients with chronic obstructive pulmonary disease that increases readmission and decreases the quality of life in these patients. Objective: This study aimed to determine the effect of controlled breathing exercises on Anxiety and Arterial Oxygen Saturation in chronic obstructive pulmonary disease in the intensive care u...
متن کاملبررسی و مقایسه تاثیر دیازپام وریدی با میدازولام وریدی به عنوان پیش داروی بیهوشی بر چگونگی اشباع اکسیژن خون شریانی قبل از شروع عمل جراحی در بیماران ریسک یک تحت بیهوشی عمومی در اطاق عمل یکی از ...
This research, which is semi- experimental is focused on the influence and comparison intravenous diazepam with intravenous midazolam as premedication in anesthesia on the saturation arterial blood oxygen before surgical operation, "pan patients who are in risk one under general anesthesia in the operating rooms of the hospitals affiliated to Iran University of Medical Sciences and Heal...
متن کاملDyspnea assessment and adverse events during sputum induction in COPD
BACKGROUND The inhalation of normal or hypertonic saline during sputum induction (SI) may act as an indirect bronchoconstrictive stimulus leading to dyspnea and lung function deterioration. Our aim was to assess dyspnea and adverse events in COPD patients who undergo SI following a safety protocol. METHODS Sputum was induced by normal and hypertonic (4.5%) saline solution in 65 patients with ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 7 3 شماره
صفحات -
تاریخ انتشار 1994