Safety Profile of Liver FibroScan in Patients with Cardiac Pacemakers or Implantable Cardioverter-Defibrillators

نویسندگان

  • Yin Chan
  • Stephanie Pranke
  • Farid Rashidi
  • Shravan Nosib
  • Lawrence Worobetz
چکیده

Background. Emerging evidence suggests that nonalcoholic fatty liver disease (NAFLD) is associated with coronary artery diseases and arrhythmias. The FibroScan (Echosens, France), a widely available, noninvasive device, is able to detect liver fibrosis and steatosis within this patient population. However, the FibroScan is currently contraindicated in patients with cardiac pacemakers (PM) or implantable cardioverter-defibrillators (ICD). Objective. To determine the safety profile of FibroScan testing in patients with PM or ICD. Methods. Consecutive outpatients undergoing routine device interrogations at a tertiary level teaching hospital underwent simultaneous liver stiffness measurements. PM or ICD performance data, device types, patient demographics, medical history, and previous laboratory and conventional liver imaging results were collected. Results. Analysis of 107 subjects with 33 different types of implanted cardiac devices, from 5 different companies (Medtronic, Sorin, ELA Medical, Boston Scientific, and St. Jude), did not demonstrate any adverse events as defined by abnormal device sensing/pacing or ICD firing. This population included high risk subjects undergoing active pacing (n = 53) and with right pectoral PM placement (n = 1). None of the subjects had any clinical signs of decompensated congestive heart failure or cirrhosis during the exam. Conclusion. TE with FibroScan can be safely performed in patients with PM or ICD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Erosive Pressure Dermatitis Associated with Cardiac Pacemaker

Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...

متن کامل

Safety of magnetic resonance imaging in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices.

Magnetic resonance imaging (MRI) in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices is sometimes a risky procedure. Thus MRI in these patients should be performed when it is the only examination able to help with the diagnosis. Moreover the diagnostic benefit must outweigh the risks. Coronary artery stents, prosthetic cardiac valves, metal sternal sutur...

متن کامل

Staphylococcus aureus bacteremia in patients with permanent pacemakers or implantable cardioverter-defibrillators.

BACKGROUND Although cardiac device infections (CDIs) are a devastating complication of permanent pacemakers or implantable cardioverter-defibrillators, the incidence of CDI in patients with bacteremia is not well defined. The objective of this study was to determine the incidence of CDI among patients with permanent pacemakers or implantable cardioverter-defibrillators who develop Staphylococcu...

متن کامل

Radiotherapy in patients with pacemakers and implantable cardioverter defibrillators: a literature review.

An increasing number of patients with implantable cardiac rhythm devices undergo radiotherapy (RT) for cancer and are thereby exposed to the risk of device failure. Current safety recommendations seem to have limitations by not accounting for the risk of pacemakers and implantable cardioverter defibrillators malfunctioning at low radiation doses. Besides scant knowledge about optimal safety mea...

متن کامل

Capsule endoscopy in patients with cardiac pacemakers and implantable cardioverter-defibrillators - a retrospective multicenter investigation.

BACKGROUND & AIMS Capsule endoscopy (CE) is an established tool for the investigation of the small intestine. The Food and Drug Administration, Given Imaging and Olympus have not recommended the use of capsule endoscopy in patients with cardiac pacemakers and implantable cardioverter defibrillators (ICDs). The aim of this retrospective study was to investigate the safety of capsule endoscopy sy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017