Mechanical properties of the everolimus-eluting bioresorbable vascular scaffold compared to the metallic everolimus-eluting stent

نویسندگان

  • Daniel Dalos
  • Clemens Gangl
  • Christian Roth
  • Lisa Krenn
  • Sabine Scherzer
  • Markus Vertesich
  • Irene Lang
  • Gerald Maurer
  • Thomas Neunteufl
  • Rudolf Berger
  • Georg Delle-Karth
چکیده

BACKGROUND Everolimus-eluting bioresorbable vascular scaffolds (BVS) represent an innovative treatment option for coronary artery disease. Clinical and angiographic results seem promising, however, data on its immediate procedural performance are still scarce. The aim of our study was to assess the mechanical properties of BVS by Optical Coherence Tomography (OCT) in clinical routine. METHODS Post-implantation OCT images of 40 BVS were retrospectively compared to those of 40 metallic everolimus-eluting stents (EES). Post-procedural device related morphological features were assessed. This included incidences of gross underexpansion and the stent eccentricity index (SEI, minimum/maximum diameter) as a measure for focal radial strength. RESULTS Patients receiving BVS were younger than those with EES (54.0 ± 11.2 years versus 61.7 ± 11.4 years, p = 0.012), the remaining baseline, vessel and lesion characteristics were comparable between groups. Lesion pre-dilatation was more frequently performed and inflation time was longer in the BVS than in the EES group (n = 34 versus n = 23, p = 0.006 and 44.2 ± 12.8 versus 25.6 ± 8.4 seconds, p < 0.001, respectively). There were no significant differences in maximal inflation pressures and post-dilatation frequencies with non-compliant balloons between groups. Whereas gross device underexpansion was not significantly different, SEI was significantly lower in the BVS group (n = 12 (30 %) versus n = 14 (35 %), p = 0.812 and 0.69 ± 0.08 versus 0.76 ± 0.09, p < 0.001, respectively). There was no difference in major adverse cardiac event-rate at six months. CONCLUSION Our data show that focal radial expansion was significantly reduced in BVS compared to EES in a clinical routine setting using no routine post-dilatation protocol. Whether these findings have impact on scaffold mid-term results as well as on clinical outcome has to be investigated in larger, randomized trials.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Outcomes From The Bioresorbable Vascular Scaffold: Is There A Role for Them?

The risk of stent thrombosis and restenosis with the second generation drug eluting stents remains. The bioresorbable vascular scaffold is a third generation stent and overcomes the problems associated with drug eluting metallic stents. The bioresorbable vascular scaffold completely absorbs within the coronary vessel over 3-5 years. Multiple trials in patients with non complex coronary disease ...

متن کامل

Long-Term Efficacy and Safety of Everolimus-Eluting Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Metallic Stents

Second-generation metallic drug-eluting stents (DES) have been widely recommended for percutaneous coronary intervention. One of the main drawbacks of these devices is the risk of late adverse events (ie, beyond 1 year), particularly repeat revascularization, which are partly related to the persistence of the metallic stents in the coronary artery wall. In this context, the bioresorbable vascul...

متن کامل

Comparison of everolimus- and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds: Two-year clinical outcomes of the EVERBIO II trial.

BACKGROUND Data from randomized controlled trials have shown that the ABSORB BVS is non-inferior to Cobalt Chromium everolimus-eluting stents at 2years. METHODS & RESULTS The EVERBIO II trial (Comparison of Everolimus- and Biolimus-Eluting Coronary Stents with Everolimus-Eluting Bioresorbable Vascular Scaffold) is a single-center, assessor-blind, randomized controlled trial enrolling 240 pati...

متن کامل

Bioresorbable Scaffolds versus Metallic Stents in Routine PCI.

BACKGROUND Bioresorbable vascular scaffolds were developed to overcome the shortcomings of drug-eluting stents in percutaneous coronary intervention (PCI). We performed an investigator-initiated, randomized trial to compare an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent in the context of routine clinical practice. METHODS We randomly assigned 1845 patie...

متن کامل

Long-Term Efficacy and Safety of Everolimus-Eluting Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Metallic Stents: A Meta-Analysis of Randomized Trials.

BACKGROUND Data regarding the long-term efficacy and safety of everolimus-eluting bioresorbable vascular scaffolds (BVS) compared with everolimus-eluting stents are limited. This meta-analysis aimed to compare the long-term outcomes with both devices. METHODS AND RESULTS Randomized trials reporting clinical outcomes beyond 1 year and comparing BVS with everolimus-eluting stents were included....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -