Usage of Industrial Computed Tomography for Evaluation of Custom-Made Implants

نویسندگان

  • Radovan Hudak
  • Jozef Zivcák
  • Teodor Tóth
  • Jaroslav Majernik
  • Martin Lisý
چکیده

Development of additive technologies and biocompatible materials facilitated their use in the custom-made implants manufacture. Verification of custommade implants manufactured using the additive manufacturing technologies is the key task to be fulfilled prior to the clinical application of an implant. It consists of parameters verification within individual steps, from a software design, through manufacturing, surface finishing, up to finalization of a medical product. The article presents possible uses of a 3D printing and the computed tomography (Metrotom 1500, Carl Zeiss, Germany) for the verification of selected parameters of customized implants manufactured using the Direct Metal Laser Sintering (DMLS) technology with the EOSINTM280 equipment (EOS GmbH, Germany) from the biocompatible titanium alloy Ti-6Al-4V (Grade 5). The article describes the possibilities of the computed tomography use in the verification of implant shapes and external dimensions, as well as internal structure. The internal structure means the implant porosity assessment. R. Hudák (B) · J. Živčák · T. Tóth Faculty of Mechanical Engineering, Department of Biomedical Engineering and Measurement, Technical University of Košice, Letná 9, 042 00 Košice, Slovakia e-mail: [email protected] J. Živčák e-mail: [email protected] T. Tóth e-mail: [email protected] J. Majerník Faculty of Medicine, Department of Medical Informatics,University in Košice, Trieda SNP 1, 040 11 Košice, Slovakia e-mail: [email protected] M. Lisý CEIT Biomedical Engineering, Tolstého 3/6, 040 01 Košice, Slovakia e-mail: [email protected] © Springer International Publishing Switzerland 2016 R. Bris et al. (eds.), Applications of Computational Intelligence in Biomedical Technology, Studies in Computational Intelligence 606, DOI 10.1007/978-3-319-19147-8_2 29

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Metal Artifact Reduction software in Computed Tomography

Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...

متن کامل

Effect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro

Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements. Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted...

متن کامل

Evaluation the Accuracy of Lineartomography in Determining the Quantity of Maxillary Bone

Background & Aims: The accuracy of dental implants has increased in recent years. An accurate radiography from the region is needed for precise treatment planning in implants and for determining prognosis of treatment. Because this technique can demonstrate the buccolingual aspect, and due to its lower radiation dose, lower cost, and availability, in comparison with computed tomography, lineart...

متن کامل

بررسی رابطه بین دانسیته استخوانی حاصل ازCone-Beam Computed Tomography با میزان ثبات اولیه ایمپلنت دندانی

Introduction & Objective: Study of bone quality before treatment is very important. The aims of this study were to assess bone quality with density values obtained by cone-beam computed tomography (CBCT) and to determine the correlations between bone density and primary stability of dental implants. Materials & Methods: In this experimental in vitro study 32 implants were inserted into fresh ...

متن کامل

7.01.144 Patient-Specific Cutting Guides and Custom Knee Implants

Custom knee implants and patient-specific instrumentation (PSI) have been developed as alternatives to off-theshelf implants and conventional cutting guides for joint arthroplasty. Custom implants and patient-specific cutting guides are constructed with the aid of preoperative 3-dimensional computed tomography (CT) or magnetic resonance imaging (MRI) scans and proprietary planning software. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015