Accuracy and Usability of a Self-Administered 6-Minute Walk Test Smartphone Application.

نویسندگان

  • Gabriel C Brooks
  • Eric Vittinghoff
  • Sivaraman Iyer
  • Damini Tandon
  • Peter Kuhar
  • Kristine A Madsen
  • Gregory M Marcus
  • Mark J Pletcher
  • Jeffrey E Olgin
چکیده

BACKGROUND The 6-minute walk test (6MWT) independently predicts congestive heart failure severity, death, and heart failure hospitalizations, but must be administered in clinic by qualified staff on a premeasured course. As part of the Health eHeart Study, we sought to develop and validate a self-administered 6MWT mobile application (SA-6MWTapp) for independent use at home by patients. METHODS AND RESULTS We performed a validation study of an SA-6MWTapp in 103 participants. In phase 1 (n=52), we developed a distance-estimation algorithm for the SA-6MWTapp by comparing step counts from an Actigraph and measured distance on a premeasured 6MWT course with step counts and estimated distance obtained simultaneously from our SA-6MWTapp (best estimation algorithm, r=0.89 [95% confidence interval 0.78-0.99]). In phase 2, 32 participants (including those with congestive heart failure and pulmonary hypertension) used the SA-6MWTapp independently in clinic, and the distance estimated by the SA-6MWTapp was compared with the measured distance (r=0.83 [95% confidence interval 0.79-0.92]). In phase 3, 19 patients with congestive heart failure and pulmonary hypertension consecutively enrolled from clinic performed 3.2±1 SA-6MWTapp tests per week at home over 2 weeks. Distances estimated from the SA-6MWTapp during home 6MWTs were highly repeatable (coefficient of variation =4.6%) and correlated with in-clinic-measured distance (r=0.88 [95% confidence interval 0.87-0.89]). Usability surveys performed during the second (in-clinic) and third (at-home) phases demonstrated that the SA-6MWTapp was simple and easy to use independently. CONCLUSIONS An SA-6MWTapp is easy to use and yields accurate repeatable measurements in the clinic and at home.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Smartphone-based application for training outpatient cardiac rehabilitation: Design and usability evaluation

Introduction: Due to the increasing trend of heart diseases and their complications, programs such as cardiac rehabilitation can reduce the complications and faster recovery of patients. Therefore, the aim of this study was to design and evaluate the usability of smartphone-based application for training outpatient cardiac rehabilitation. Materials and Methods: This applied-developmental study ...

متن کامل

Design and Development of an Educational Mobile Application for Autism Spectrum Disorder

Introduction: Autism is one of the most common neurodevelopmental disorders that is diagnosed late due to parentschr('39') unfamiliarity with the disorder. Lack of knowledge of parents is one of the major problems of this disorder. The objective of this study was to develop an educational smartphone-based application for autism spectrum disorder specific for parents. Method: This study was an a...

متن کامل

Design and Development of an Educational Mobile Application for Autism Spectrum Disorder

Introduction: Autism is one of the most common neurodevelopmental disorders that is diagnosed late due to parentschr('39') unfamiliarity with the disorder. Lack of knowledge of parents is one of the major problems of this disorder. The objective of this study was to develop an educational smartphone-based application for autism spectrum disorder specific for parents. Method: This study was an a...

متن کامل

Develop of native aerobic power prediction equation by the 6-minute walk test in healthy child

Aerobic power (VO2max) is an important indicator of the health and physical fitness. Executive problems in direct VO2max measurement has led to developing sub-maximal aerobic power prediction equations. The purpose of present study was to develop native aerobic power prediction equation based on 6-Minute Walk Test (6MWT) and body composition indices in children. In 192 healthy children (8 to 12...

متن کامل

Periodic sound-based 6-minute walk test forpatients with Duchenne muscular dystrophy:a preliminary study.

[Purpose] The purpose of this study was to verify if a periodic sound-based 6-minute walk test with the best periodic sound could be used to evaluate physical endurance more precisely than the conventional 6-minute walk test. [Subjects] The subjects were healthy subjects and 6 ambulant patients with Duchenne muscular dystrophy. [Methods] The subjects initially walked for 1 minute to a long-inte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Heart failure

دوره 8 5  شماره 

صفحات  -

تاریخ انتشار 2015