Intrathoracic pressure regulator during continuous-chest-compression advanced cardiac resuscitation improves vital organ perfusion pressures in a porcine model of cardiac arrest.
نویسندگان
چکیده
BACKGROUND A novel device, the intrathoracic pressure regulator (ITPR), combines an inspiratory impedance threshold device (ITD) with a vacuum source for the generation of controlled -10 mm Hg vacuum in the trachea during cardiopulmonary resuscitation (CPR) while allowing positive pressure ventilation. Compared with standard (STD) CPR, ITPR-CPR will enhance venous return, systemic arterial pressure, and vital organ perfusion in both porcine models of ventricular fibrillation and hypovolemic cardiac arrest. METHODS AND RESULTS In protocol 1, 20 pigs (weight, 30+/-0.5 kg) were randomized to STD-CPR or ITPR-CPR. After 8 minutes of untreated ventricular fibrillation, CPR was performed for 6 minutes at 100 compressions per minute and positive pressure ventilation (100% O2) with a compression-to-ventilation ratio of 15:2. In protocol 2, 6 animals were bled 50% of their blood volume. After 4 minutes of untreated ventricular fibrillation, interventions were performed for 2 minutes with STD-CPR and 2 minutes of ITPR-CPR. This sequence was repeated. In protocol 3, 6 animals after 8 minutes of untreated VF were treated with ITPR-CPR for 15 minutes, and arterial and venous blood gases were collected at baseline and minutes 5, 10, and 15 of CPR. A newer, leak-proof ITPR device was used. Aortic, right atrial, endotracheal pressure, intracranial pressure, and end-tidal CO2 values were measured (mm Hg); common carotid arterial flow also was measured (mL/min). Coronary perfusion pressure (diastolic; aortic minus right atrial pressure) and cerebral perfusion pressure (mean arterial minus mean intracranial pressure) were calculated. Unpaired Student t test and Friedman's repeated-measures ANOVA of ranks were used in protocols 1 and 3. A 2-tailed Wilcoxon signed-rank test was used for analysis in protocol 2. Fischer's exact test was used for survival. Significance was set at P<0.05. Vital organ perfusion pressures and end-tidal CO2 were significantly improved with ITPR-CPR in both protocols. In protocol 1, 1-hour survival was 100% with ITPR-CPR and 10% with STD-CPR (P=0.001). Arterial blood pH was significantly lower and Paco2 was significantly higher with ITPR-CPR in protocol 1. Arterial oxygen saturation was 100% throughout the study in both protocols. Paco2 and Pao2 remained stable, but metabolic acidosis progressed, as expected, throughout the 15 minutes of CPR in protocol 3. CONCLUSIONS Compared with STD-CPR, use of ITPR-CPR improved hemodynamics and short-term survival rates after cardiac arrest.
منابع مشابه
Evaluation of a prototypic inspiratory impedance threshold valve designed to enhance the efficiency of cardiopulmonary resuscitation.
OBJECTIVE Assess a prototype inspiratory impedance threshold valve (ITV) designed to enhance vital organ circulation during standard and active compression/decompression cardiopulmonary resuscitation (CPR). BACKGROUND The ITV attaches to commonly used airway assist devices and decreases intrathoracic pressure during the decompression (chest recoil) phase of CPR by creating a vacuum within the...
متن کاملComparison of CPR outcome predictors between rhythmic abdominal compression and continuous chest compression CPR techniques.
OBJECTIVE Bystander cardiopulmonary resuscitation (CPR) provides treatment for out-of-hospital cardiac arrest since perfusion of vital organs is critical to resuscitation. Alternatives to standard CPR are evaluated for effectiveness based upon outcome predictive metrics and survival studies. This study focuses on evaluating the performance of rhythmic-only abdominal compression CPR (OAC-CPR) re...
متن کاملUse of an inspiratory impedance threshold valve during cardiopulmonary resuscitation: a progress report.
Building upon studies on the mechanism of active compression-decompression (ACD) cardiopulmonary resuscitation, a new inspiratory impedance threshold valve has been developed to enhance the return of blood to the thorax during the decompression phase of CPR. Use of this device results in a greater negative intrathoracic pressure during chest wall decompression. This leads to improved vital orga...
متن کاملWhat is the optimal chest compression-ventilation ratio?
PURPOSE OF REVIEW Despite a more widespread knowledge of basic cardiopulmonary resuscitation maneuvers in the community, the survival rate for patients with cardiac arrest has remained essentially unchanged in the past 30 years. Over the past few decades, many different compression-ventilation ratios have been studied in terms of best coronary and cerebral oxygen delivery, restoration of sponta...
متن کاملReducing ventilation frequency during cardiopulmonary resuscitation in a porcine model of cardiac arrest.
INTRODUCTION American Heart Association/American College of Cardiology guidelines recommend a compression-to-ventilation ratio (C/V ratio) of 15:2 during cardiopulmonary resuscitation (CPR) for out-of-the-hospital cardiac arrest. Recent data have shown that frequent ventilations are unnecessary and may be harmful during CPR, since each positive-pressure ventilation increases intrathoracic press...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 112 6 شماره
صفحات -
تاریخ انتشار 2005