Limits of Tumor Detectability in Nuclear Medicine and PET
نویسنده
چکیده
OBJECTIVE Nuclear medicine is becoming increasingly important in the early detection of malignancy. The advantage of nuclear medicine over other imaging modalities is the high sensitivity of the gamma camera. Nuclear medicine counting equipment has the capability of detecting levels of radioactivity which exceed background levels by as little as 2.4 to 1. This translates to only a few hundred counts per minute on a regular gamma camera or as few as 3 counts per minute when using coincidence detection on a positron emission tomography (PET) camera. MATERIAL AND METHODS We have experimentally measured the limits of detectability using a set of hollow spheres in a Jaszczak phantom at various tumor-to-background ratios. Imaging modalities for this work were (1) planar, (2) SPECT, (3) PET, and (4) planar camera with coincidence detection capability (MCD). RESULTS When there is no background (infinite contrast) activity present, the detectability of tumors is similar for PET and planar imaging. With the presence of the background activity , PET can detect objects in an order of magnitude smaller in size than that can be seen by conventional planar imaging especially in the typical clinical low (3:1) T/B ratios. The detection capability of the MCD camera lies between a conventional nuclear medicine (planar / SPECT) scans and the detection capability of a dedicated PET scanner. CONCLUSION Among nuclear medicine's armamentarium, PET is the closest modality to CT or MR imaging in terms of limits of detection. Modern clinical PET scanners have a resolution limit of 4 mm, corresponding to the detection of tumors with a volume of 0.2 ml (7 mm diameter) in 5:1 T/B ratio. It is also possible to obtain better resolution limits with dedicated brain and animal scanners. The future holds promise in development of new detector materials, improved camera design, and new reconstruction algorithms which will improve sensitivity, resolution, contrast, and thereby further diminish the limits of tumor detectability. CONFLICT OF INTEREST None declared.
منابع مشابه
18F-FDG PET/CT in the diagnosis of tumor thrombus from anaplastic thyroid carcinoma in a young boy
Anaplastic thyroid carcinoma is an uncommon, highly aggressive malignancy usually presenting in the elderly. An eighteen year old boy was recently diagnosed as anaplastic carcinoma of the thyroid. PET/CECT scan performed for staging, revealed a large FDG avid heterogeneously enhancing thyroid mass with bilateral jugular venous thrombosis, which also showed increase...
متن کاملImportance of defect detectability in Positron Emission Tomography imaging of abdominal lesions
Objective(s): This study was designed to assess defect detectability in positron emission tomography (PET) imaging of abdominal lesions. Methods: A National Electrical Manufactures Association International Electrotechnical Commission phantom was used. The simulated abdominal lesion was scanned for 10 min using dynamic list-mode acquisition method. Images, acquired with scan duration of 1-10 mi...
متن کاملRecent Advances in PET-MR Hybrid contrast agent
Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...
متن کاملFDG-PET/CT and CT findings of a benign solitary fibrous tumor of the kidney: correlation with pathology
Herein, we report the F-18 fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) findings of a benign solitary fibrous tumor (SFT) of the kidney. The patient was a 63-year-old woman with a mass in the right kidney (10×9.7 cm), incidentally found on CT images. The CT scan showed a lobulated tumor arising from the hilum of the right kidney. The tumor consisted o...
متن کاملThe application of unconventional PET tracers in nuclear medicine
The production and application of PET tracers has been a unique step in the progress of nuclear medicine in last two decades. The most important PET tracers include F-18, C-11 and N-13 radioisotopes and many nuclear medicine centers throughout the globe are using them. However some new tracers are under their way to the mass administration, currently being in th...
متن کامل