Hot and cold contrasts in high-resolution Tc-99m planar scintigraphy: a survey of fifty-two camera heads using the PICKER thyroid phantom.
نویسنده
چکیده
This study was aimed at comparing the sensitivity and hot and cold contrasts obtained when imaging the PICKER thyroid phantom using gamma cameras fitted with either their ultra-high or high-resolution low-energy parallel hole collimator. Seventeen camera models from Elscint, General Electric, Siemens and Sopha Medical Vision were involved in the study for a total of 30 cameras and 52 camera heads. A single operator conducted the study in order to minimize the impact of human factors. The phantom contained about 74MBq (99m)Tc and was imaged at 10cm from the collimator face with the energy window that are recommended by the camera manufacturer. A total of 1 million counts were accumulated. Hot and cold contrasts were in mean of about 0.05 higher when using an ultra-high-resolution than when using a high-resolution low-energy collimator. This higher contrast was obtained at the expense of a mean reduction in sensitivity of 30%. In particular, Elscint cameras demonstrated a 30% lower sensitivity whatever the collimator type. The Sopha Medical Vision DST and DSX cameras and the General Electric Magicam camera offered the lowest contrasts among the cameras with a high-resolution collimator. Although this was accompanied by a higher than the mean sensitivity for the DST and DSX, the Magicam demonstrated sensitivity roughly identical to the mean of all the cameras with a high-resolution collimator.
منابع مشابه
Determination of Optimum Planar Imaging Parameters for Small Structures with Diameters Less Than the Resolution of the Gamma Camera
Introduction: The limited spatial resolution of the gamma camera hinders the absolute quantification of planar images of small structures. The imaged structures are affected by partial volume effects (PVEs), which can spread activity and lead to underestimation of the regional distribution. The use of optimum planar parameters reduces the impact of the limited spatial resolution of the gamma c...
متن کاملIncidental thyroid uptake during 99mTc-methylene diphosphonate bone scintigraphy in oncologic patients
Introduction: Extraosseous accumulation of 99mTc – methylene diphosphonate (MDP) may be due to neoplastic, dystrophic, hormonal, inflammatory, ischemic, traumatic or excretory disorders. 99mTc-MDP incidental thyroid uptake is not frequent and is possibly caused by the presence of dystrophic or metastatic calcification, biopsy procedure and presence of beni...
متن کاملPercutaneous microwave ablation of thyroid nodules: efficacy evaluation with 99m Tc - pertechnetate and 99mTc-MIBI functional imaging
Background: Local ablative treatments play an important role for patients who cannot be treated surgically. Radiofrequency ablation is a well-established alternative to surgical treatment of thyroid nodules, however it also has disadvantages. Microwave ablation (MWA) is a new minimally invasive treatment promising several improvements. The aim of this retrospective study was to evaluate the eff...
متن کاملComparison of Iodine-131 Absorbed Dose and Technetium-99m in Thyroid Scanning Using the MCNPX Simulation Code in the ORNL-MIRD Phantom
Thyroid scanning is performed to examine the thyroid gland disorders using 99mTc. Through the obtained images can evaluate the size of the thyroid gland, the amount of its removal compared with the salivary gland, examine the thyroid nodules and its performance impairments. According to the scan view, it is possible to differentiate between hot and cold thyroid nodules that need different thera...
متن کاملAbsent radiotracer uptake in thyroid gland in parathyroid scintigraphy with 99mTc-MIBI: A case report
Localization of 99mTc- hexakis-2-methoxyisobutylisonitrile (99mTc-MIBI) by parathyroid adenomas is well known, and this warrants MIBI scan to evaluate suspected parathyroid adenoma in primary hyperparathyroidism. Typically, the radionuclide concentrates in both the thyroid gland and parathyroid adenoma in early images, and later on delayed images washes out slowly from the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics
دوره 26 3 شماره
صفحات -
تاریخ انتشار 2010