Comparison of superior vena cava and femoroiliac vein pressure according to intra-abdominal pressure
نویسندگان
چکیده
BACKGROUND Previous studies have shown a good agreement between central venous pressure (CVP) measurements from catheters placed in superior vena cava and catheters placed in the abdominal cava/common iliac vein. However, the influence of intra-abdominal pressure on such measurements remains unknown. METHODS We conducted a prospective, observational study in a tertiary teaching hospital. We enrolled patients who had indwelling catheters in both superior vena cava (double lumen catheter) and femoroiliac veins (dialysis catheter) and into the bladder. Pressures were measured from all the sites, CVP, femoroiliac venous pressure (FIVP), and intra-abdominal pressure. RESULTS A total of 30 patients were enrolled (age 62 ± 14 years; SAPS II 62 (52-76)). Fifty complete sets of measurements were performed. All of the studied patients were mechanically ventilated (PEP 3 cmH20 (2-5)). We observed that the concordance between CVP and FIVP decreased when intra-abdominal pressure increased. We identified 14 mmHg as the best intra-abdominal pressure cutoff, and we found that CVP and FIVP were significantly more in agreement below this threshold than above (94% versus 50%, P = 0.002). CONCLUSIONS We reported that intra-abdominal pressure affected agreement between CVP measurements from catheter placed in superior vena cava and catheters placed in the femoroiliac vein. Agreement was excellent when intra-abdominal pressure was below 14 mmHg.
منابع مشابه
Intra-Abdominal Venous Pressure During Laparoscopic Cholecystectomy
Superior vena cava (SVC) and inferior vena cava (IVC) pressures were measured serially during laparoscopic cholecystectomy in which the intra-abdominal pressure was maintained at 12 mmHg. The influences of alteration of position from 15 degrees head-down to 15 degrees head-up and of the operative procedure of holding the gallbladder up to the right subphrenic space on SVC and IVC pressures were...
متن کاملThe efficacy of inferior vena cava diameters and the jugular vein in assessing fluid resuscitation
Objective: Fluid resuscitation is necessary in almost all critical patients. The central venous pressure (CVP) is a well-established method of assessing resuscitation. Recently, there have been attempts to investigate less invasive methods like the diameters of inferior vena cava (IVC) or the jugular vein. We aimed to investigate this method in our research.Methods: Seventy eight critical...
متن کاملIncreasing abdominal pressure with and without PEEP: effects on intra-peritoneal, intra-organ and intra-vascular pressures
BACKGROUND Intra-organ and intra-vascular pressures can be used to estimate intra-abdominal pressure. The aim of this prospective, interventional study was to assess the effect of PEEP on the accuracy of pressure estimation at different measurement sites in a model of increased abdominal pressure. METHODS Catheters for pressure measurement were inserted into the stomach, urinary bladder, peri...
متن کاملMeasurement of Central Venous Pressure via the Femoral Route in Abdominal Compartment Syndrome
Introduction: Femoral vein catheterization provides an alternative route of access to central veins, is technically easy and relatively safe. There is good evidence of a general agreement between intrathoracic central venous pressure (CVP) and CVP measured in the iliofemoral veins or inferior vena cava in critically ill patients. This agreement is not well documented when intra-abdominal pressu...
متن کاملThe lack of value of hepato - jugular reflux as a sign of heart failure R . HAIDER
An investigation was carried out of the diagnostic value of hepato-jugular reflux in patients with heart failure. The effect of abdominal compression on superior vena cava pressure was assessed in patients with and without heart failure. In four of the six patients without congestive cardiac failure, during compression, whether applied in the right hypochondrium or left iliac fossa, there was a...
متن کامل