Elastic modulus of a triple-stranded stainless steel arch wire via three- and four-point bending.
نویسندگان
چکیده
The modulus of elasticity (E) was determined in simple three- and four-point bending for an 0.0175" (3 X 0.008") stainless steel arch wire. Using variable light loads (10-160 g) to limit the elastic deflection of a wire to less than 5% of its beam length, the force-deflection profiles were determined for three nominal span lengths (L = 0.35", 0.75", and 1.00") in three-point bending and three nominal inner span lengths (L2 = 0.17", 0.40", and 0.50") in four-point bending (single outer span length, L = 1.00"). By assuming that each wire could be considered as a bundle of frictionless, tightly wound helical springs (i.e., strands), in which both the Young's modulus (E) and the shear modulus (G) contribute to the overall stiffness, values for E equaled 28.6 +/- 0.6 X 10(6) and 29.6 +/- 0.9 X 10(6) psi in three- and four-point bending, respectively. In addition, by using simple beam theory, the values of E for the 0.010" and 0.018" single-stranded wires were measured and equaled 27.2 +/- 0.3 X 10(6) and 27.8 +/- 0.7 X 10(6) psi in three-point bending, and 27.9 +/- 0.7 and 27.8 +/- 1.2 X 10(6) psi in four-point bending, respectively. Despite the fact that the elastic moduli of all three wires were significantly different (p less than 0.001), the results corroborated the metallurgical literature in which E spanned 27.8-30.2 X 10(6) psi. This was in contrast to the dental literature, in which a broader range of values has been reported, i.e., 18.3-38.0 X 10(6) psi.
منابع مشابه
Galvanic Corrosion among Different Combination of Orthodontic Archwires and Stainless Steel Brackets
Introduction: The aim of this study was to assess the galvanic behavior of different bracket and archwire combinations that are commonly used in orthodontic treatments. Methods: Three types of orthodontic archwires with a diameter of 0.016×0.022 inch and 80 standard edgewise maxillary central incisor brackets were selected. Three groups consisted of different wire-bracket couples and one group ...
متن کاملMechanical evaluation of quad-helix appliance made of low-nickel stainless steel wire.
OBJECTIVE The objective of this study was to test the hypothesis that there is no difference between stainless steel and low-nickel stainless steel wires as regards mechanical behavior. Force, resilience, and elastic modulus produced by Quad-helix appliances made of 0.032-inch and 0.036-inch wires were evaluated. METHODS Sixty Quad-helix appliances were made, thirty for each type of alloy, be...
متن کاملSynergistic effect of wire bending and salivary pH on surface properties and mechanical properties of orthodontic stainless steel archwires
BACKGROUND The aim of this study was to investigate the corrosive behaviour of stainless steel archwires in a more clinically relevant way by bending and exposing to various pH. METHODS One hundred and twenty pieces of rectangular stainless steel wires (0.43 × 0.64 mm) were randomly assigned into four groups. In each group, there were 15 pieces of bent wires and 15 straight ones. Prior to mea...
متن کاملRoot resorption after leveling with super-elastic and conventional steel arch wires: a prospective study
BACKGROUND The aim of this prospective study was to compare root resorption after the leveling phase of treatment, performed by either super-elastic or conventional multi-stranded stainless steel arch wires. METHODS From a total of 156 future orthodontic patients in a private clinic, 82 were included in the study after excluding those who earlier had orthodontic or endodontic treatment or sig...
متن کاملDeactivation force-deflection behavior of multistranded stainless steel wires.
This investigation measured the deactivation (unloading) force-deflection behavior of selected multistranded stainless steel orthodontic wires. The guidelines from the revised American National Standards Institute/American Dental Association Specification No. 32 for orthodontic wires (type 2, nonlinear elasticity) were used to perform a 3-point bending test to obtain data for the deactivation f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of dental research
دوره 63 10 شماره
صفحات -
تاریخ انتشار 1984