Lymph and pulmonary response to isobaric reduction in plasma oncotic pressure in baboons.
نویسندگان
چکیده
Plasma colloid osmotic pressure was reduced by 76% (from 19.6 +/- 0.6 to 4.7 +/- 1.5 mm Hg) in five baboons while pulmonary capillary hydrostatic pressure was maintained at a normal level. This resulted in fluid retention, weight gain, peripheral edema and ascites, but no pulmonary edema. Thoracic duct lymph flow increased 6-fold and pulmonary lymph flow 7-fold. Thoracic duct lymph had a lower colloid osmotic pressure (2.0 +/- 0.7 mm Hg) than plasma (4.7 +/- 1.5 mm Hg), whereas the colloid osmotic pressure of pulmonary lymph (4.7 +/- 0.7 mm Hg) was the same as that of plasma. The lymph-plasma ratio for albumin fell in thoracic duct lymph but remained unchanged in pulmonary lymph. The difference between plasma colloid osmotic pressure and pulmonary artery wedge pressure decreased from 15.3 +/- 1.9 to -0.7 +/- 2.9 mm Hg. Despite this increase in filtration force, the lungs were protected from edema formation by a decrease of 11 mm Hg in pulmonary interstitial colloid osmotic pressure and a 7-fold increase in lymph flow.
منابع مشابه
The effect of sepsis and reduced colloid osmotic pressure on pulmonary edema.
The interrelationship of hydrostatic pressure and osmotic forces across the capillary membrane are described by the Starling equation [lo]. Increasing pulmonary capillary hydrostatic pressure is a cause of pulmonary edema 131. Pulmonary edema develops at a lower hydrostatic pressure when plasma colloid oncotic pressure is lowered suggesting that the gradient between colloid oncotic pressure (CO...
متن کاملThe effects of hypoproteinemia on blood-to-lymph fluid transport in sheep lung.
We studied the effects of reducing the plasma protein concentration on flow and composition of pulmonary lymph in 12 unanesthetized sheep. Whole blood was removed while red cells were returned and lactated Ringers was infused at a rate sufficient to maintain pulmonary vascular pressures at baseline values. A 44-54% reduction in plasma protein concentration resulted in a decrease in the plasma o...
متن کاملSepsis reduces the threshold hydrostatic pressure necessary for pulmonary edema in baboons.
The threshold hydrostatic pressure necessary to produce pulmonary edema may be lowered by a decrease in plasma colloid oncotic pressure (COP) or an increase in capillary permeability. Sepsis is thought to increase capillary permeability. The object of this report was to assess the effect of sepsis on threshold hydrostatic pressure. In five adult male baboons a Foley catheter was inserted into t...
متن کاملInteraction of capillary, interstitial, and lymphatic forces in the canine hindpaw.
We used plethysmograph techniques to measure or calculate the tissue and capillary forces and flows (capillary pressure, tissue and plasma oncotic pressure, transcapillary pressure drop, lymph flow, and interstitial pressure) in a dog hindpaw preparation in situ at three different venous pressures (PV). Since lymph was flowing from the preparation, an isovolumetric state represented an isofiltr...
متن کاملChronic Pulmonary Edema
• Clinically, the development of pulmonary edema is frequently associated with an elevation of left atrial pressure. However, overt pulmonary edema does not always occur with such pressure elevations, even when the plasma oncotic pressure is greatly exceeded. It is conceivable that a dilatation of the pulmonary lymphatic system might remove fluid from the lung and prevent, or delay, the develop...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation research
دوره 43 6 شماره
صفحات -
تاریخ انتشار 1978