A case of percutaneous modified Blalock-Taussig shunt downsize with multiple stent-in-graft technique

نویسندگان

  • Roland Fiszer
  • Malgorzata Szkutnik
  • Natalia Iashchuk
  • Jacek Bialkowski
چکیده

Corresponding author: Roland Fiszer MD, PhD, Department of Congenital Heart Diseases and Paediatric Cardiology, Medical University of Silesia, Silesian Center for Heart Diseases, 9 Curie-Skłodowskiej St, 41-800 Zabrze, Poland, phone: +48 504 125 057, e-mail: [email protected] Received: 7.10.2015, accepted: 8.12.2015. A case of percutaneous modified Blalock-Taussig shunt downsize with multiple stent-in-graft technique

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful percutaneous transluminal balloon angioplasty and thrombolysis of a thrombosed bovine mesenteric venous graft after a modified Blalock-Taussig shunt Modifiye Blalock-Taussig şantı sonrası tromboz gelişen sığır mezenterik venöz greftin transkütan yolla başarılı balon anjiyoplastisi ve trombolizi

Duktus bağımlı siyanotik doğuştan kalp hastalığı olan beş aylık erkek bebeğe 4 mm’lik sığır mezenterik ven grefti ile palyasyon amaçlı modifiye Blalock-Taussig şant ameliyatı uygulandı. Ameliyat sonrası yedinci günde tekrar tıkanan şant cerrahi olarak revize edildi. Ancak, ikinci ameliyattan altı gün sonra greftte tekrar retromboz tespit edildi. Şant materyaline perkütan yolla başarılı bir şeki...

متن کامل

Perigraft seroma complicating the modified Blalock-Taussig shunts: two consecutive instances with review of literature.

Systemic-to-pulmonary artery shunts using polytetrafluoroethylene (PTFE) (modified Blalock-Taussig shunt) are being used successfully in palliation of cyanotic congenital heart diseases. Graft thrombosis is by far the most common complication of the procedure. Persistant serum leakage through PTFE graft causing perigraft seroma is a rare but devastating complication resulting in increased durat...

متن کامل

Percutaneous closure of Blalock-Taussig shunts using Gianturco coils.

Permeability of a Blalock-Taussig shunt can increase the risk of endocarditis and ventricular overload. Percutaneous embolization of these shunts gives variable results. We report our experience in 10 patients with percutaneous closure of modified Blalock-Taussig shunts using retrograde arterial embolization with Gianturco coils. The patients' median age was 2.8 years, and their median weight w...

متن کامل

Modified Blalock-taussig Shunt ----in- Hospital Shunt Occlusion: Experience at Nicvd

A modified Blalock-Taussig shunt (mBTS) is a surgically placed graft between the systemic and pulmonary arterial circulations that redirects systemic blood flow into the pulmonary circulation. It is often placed in those with rightsided obstructive cardiac defects to increase pulmonary blood flow. Postoperative shunt patency is critical to adequate systemic oxygenation. Nevertheless, in the imm...

متن کامل

Complications of modified Blalock-Taussig shunts mimicking pulmonary disease.

The modified Blalock-Taussig shunt is commonly performed as early palliation in cyanotic congenital heart disease. To highlight unusual diagnostic problems in such patients, two cases are reported in whom shunt complications were initially diagnosed as lobar pneumonia and tuberculosis, respectively. The children, an 8 month old boy and a 3 year old boy, had false aneurysm secondary to infection...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2016