Design of a microcomputer-based densitometer system: application to serum protein electrophoresis.

نویسنده

  • W E Neeley
چکیده

We describe how a microcomputer (Apple II Plus) can be interfaced with a commercial densitometer to provide control functions, do automated data processing, and print final reports. The amplified densitometer photodetector signal is digitized, stored, and plotted on the cathode-ray tube to provide a real-time graphical display of data acquisition. The software was designed to identify automatically the five main serum protein fractions and to compute final results. Algorithms were designed to provide medically relevant comments for most of the common abnormal protein patterns, and the comments section was designed so that it could be modified to use specific comments composed by the user. A final report, printed in duplicate, contains information such as the patient's name, identifying numbers, numerical results, normal values, medically relevant comments, and a digitized high-resolution plot of the electrophoretic pattern. The densitometer was one that already had been in use for several years; the microcomputer system, software, and interfaces cost less than $2200.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution densitometry: analysis of stained albumin bands as a model for electrophoresis of serum proteins.

In discussing the principles of quantitative analysis in thin-layer media, we show that requirements for quantitative analysis are not satisfied when stained protein electrophoretic bands are scanned with a conventional rectangular-slit densitometer. We investigated a high-resolution densitometer based on a linear photodiode array as an alternative analytical tool, using stained electrophoretic...

متن کامل

Computer calculation of serum protein electrophoresis, based on peak height measurements.

A computer program has been written for off-line calculation of relative and absolute percentages of the five serum protein fractions usually seen on cellulose acetate electrophoretograms, with use of manually observed peak heights on densitometer scans. With myeloma-like peaks, both peak height and width at half-peak height must be measured. Routine application of the program saves technician ...

متن کامل

Prediction of immunoglobulins from patterns of cellulose acetate electrophoresis.

The concentrations of serum immunoglobulins (Ig) C, A, and M were correlated with specific features in the $y region of densitometer patterns of serum protein electrophoresis on cellulose acetate membranes; visual analysis of densitometer patterns permitted semiquantitative prediction of values for lgC and lgA. Important immunoglobulin abnormalities, particularly elevations of IgA, were seen in...

متن کامل

A densitometer for quantitative autoradiography.

A low cost spot densitometer system is described. This system is useful for quantitative autoradiography of local cerebral glucose utilization, blood flow, receptor binding and other applications requiring densitometry on films. The densitometer can be used alone or interfaced to a microcomputer. The densitometer consists of a photographic enlarger, a digital multimeter, and the densitometer el...

متن کامل

A Microcomputer-Based Simulator for Digital Control Systems

A microcomputer-based simulator for digital control systems is proposed. The proposed simulator is a hybrid system in which the plant is simulated by conventional method of analog computers and other parts of the system including generation of input signal is performed digitally, using a Z-80 based microcomputer. To overcome the difficulty of programming in assembly language, and at the same ti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 30 5  شماره 

صفحات  -

تاریخ انتشار 1984