Correlation of the Murmur of Interventricular Septal Defect with Pressure Differences between the Ventricles.

نویسندگان

  • S FENIG
  • J HILSENRATH
  • L STEINFELD
  • J LASSER
  • G GENKINS
  • A J GORDON
چکیده

The systolic murmur associated with interventricular septal defect presents a number of variations which have been related to the location and size of the defect, the pulmonary vascular resistance, and to the pressure gradient between the ventricles. The purpose of this investigation was to study the relation of the pressure gradient in interventricular septal defect to the time-intensity characteristics of the murmur. This was accomplished by simultaneously ?ecording pressure pulses in both ventricles together with continuous pressure differences between the ventricles, and phonocardiograms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diastolic Bulging of the Interventricular Septum Toward the Left Ventricle

Diastolic bulging of the interventricular septum (IVS) toward the left ventricle was observed by real-time cross-sectional echocardiography in three patients with primary pulmonary hypertension and one patient with secondary pulmonary hypertension after closure of an atrial septal defect. M-mode echocardiography showed a characteristic abnormal pattern of septal motion in diastole and in systol...

متن کامل

Prevalence and Etiology of Heart Murmurs in 2-24-Months-Old Infants Kerman, Iran

Background & aim: Congenital heart disease is one of the most common malformations at birth that require timely recognition and treatment. The aim of this study was to determine the prevalence and etiology of detected heart murmurs and association between congenital heart disease and heart murmurs. Recognition of murmurs etiology would help us to manage and treat them properly. Methods: In this...

متن کامل

Doppler assessment of the interventricular pressure drop in patients with ventricular septal defects.

Doppler ultrasound was used to assess the pressure drop between the ventricles in 109 infants and children (61 less than two years old) with a ventricular septal defect who underwent cardiac catheterisation. The pressure in both ventricles was measured at catheterisation in 103 patients either simultaneously through two catheters (41) or with a single catheter withdrawn across the septum or rem...

متن کامل

Reference curve of the fetal ventricular septum area by the STIC method: preliminary study.

BACKGROUND Early detection of septal changes such as septal hypertrophy commonly present in fetuses of diabetic mothers would help reduce the high rates of infant mortality. OBJECTIVE Determine reference ranges for the fetal ventricular septal area through three-dimensional ultrasound (US3D) using the STIC method (Spatio-Temporal Image Correlation). METHODS We conducted a cross-sectional st...

متن کامل

Small Ventricular Septal Defect

T HE auscultatory and phonocardiographic characteristics of ventricular septal defects have been the subject of several studies,'-5 none of them dealing specifically with the features of small defects. The present study represents an attempt to define the phonocardiographic pattern of ventricular septal defect with a small left-to-right shunt and normal pulmonary artery pressure. It was hoped t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 27  شماره 

صفحات  -

تاریخ انتشار 1965