Establishing the direct-potentiometric "normal" range for Na/K: residual liquid junction potential and activity coefficient effects.

نویسندگان

  • J D Czaban
  • A D Cormier
  • K D Legg
چکیده

The observed reference ranges for sodium and potassium as determined by direct potentiometry vary from instrument to instrument, depending on the composition of the calibration standards. To resolve the existing confusion as to which reference intervals are most appropriately considered "normal," we propose a straightforward convention (based on plasma-water concentration units) in which the difference between direct (undiluted sample) and indirect (diluted sample) methodologies is accounted for by the volume displacement effect of proteins, lipids, and other dissolved substances in a typical plasma sample. Thus, the proposed reference intervals for sodium and potassium are approximately 7% greater by direct potentiometry than by procedures involving dilution. Data consistent with this convention can be obtained with a variety of aqueous-based calibrants, provided care is taken to minimize the errors resulting from activity coefficient and liquid junction potential effects. Additional experimental results are presented to show that these effects also account for the apparent suppression of the sodium ion concentration observed in the presence of bicarbonate ion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination and Modeling of Activity Coefficients of Sodium Chloride in (Glycerol + Water) Mixtures Based on Potentiometric Measurements

In this work, the results concerning to the mean activity coefficient measurements for NaCl in the (glycerol + water) system using the potentiometric method are reported. The potentiometric measurements were performed on the galvanic cells without liquid junction of the type: Ag|AgCl|NaCl (m), glycerol (wt%), H2O (1 - wt)%|Na-ISE, in various mixed solvent systems containing 0, 5, 10,...

متن کامل

Thermodynamic Study of the Ternary Electrolyte (1-Butyl-3-methylimidazolium chloride + sodium chloride + Water) System Using Potentiometric Measurements

In this paper, the thermodynamic properties of the aqueous mixed electrolyte system containing 1-butyl-3-methylimidazolium chloride ([BMIm]Cl) and NaCl are reported based on the potentiometric method. The potentiometric measurements were performed on the galvanic cells without liquid junction of the type:Ag-AgCl [BMIm]Cl (m1), NaCl(m2), H2O│IL-...

متن کامل

Ion-selective electrodes for sodium and potassium: a new problem of what is measured and what should be reported.

For clinical purposes the activities of Na+ and K+ obtained with ion-selective electrodes in undiluted whole blood or serum should be multiplied by an appropriate factor to obtain the same values as the substance concentrations obtained by flame photometry. The factor is primarily dependent on the mass concentration of water in normal plasma divided by the molal activity coefficient of Na+ (or ...

متن کامل

Mean Activity Coefficients Measurements and Thermodynamic Modeling of the Ternary Mixed Electrolyte KCl + Lactose + Water System at T = 298.15 K

In this work, the mean activity coefficients of KCl in the KCl+lactose +water system were determined using the potentiometric method. The electromotive force measurements were carried out on the galvanic cell without liquid junction of the type: Ag|AgCl|KCl (m), lactose (wt.%), H2O (1−wt.) %|K-ISE, in various mixed solvent systems containing 0, 5,7.5, 10 and 12.5 % mass fractions of lactose. Th...

متن کامل

High-Sensitive and Selective Liquid Membrane Electrode for Direct Determination of Trace Amounts of Chromium

N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 28 9  شماره 

صفحات  -

تاریخ انتشار 1982