Moisture Equilibrium in Transformer Paper - Oil Systems

نویسنده

  • A. V. Mamishev
چکیده

he presence of moisture in a transformer deteriorates transformer insulation by decreasing both the electrical and mechanical strength. In general, the mechanical life of the insulation is reduced by half for each doubling in water content [l]; the rate of thermal deterioration of the paper is proportional to its water content [2]. Electrical discharges can occur in a high voltage region due to a disturbance of the moisture equilibrium causing a low partial discharge inception voltage and higher partial discharge intensity [ 3 ] . The migration of a small amount of moisture has been associated with flow electrification at paper/oil interfaces and is presumed to be due to charge accumulation on highly insulating interfacial dry zones [4,5]. Water in mineral oil transformers also brings the risk of bubble formation when desorption of water from the cellulose increases the local concentration of gases in the oil [6] . The importance of moisture presence in paper and oil systems has been recognized since the 1920s. It is useful to know the moisture partitioning curves between oil and paper under equilibrium conditions. When the transformer is in equilibrium operation, this provides a quick way of examining the moisture content in paper to predict future failure by measuring the moisture in oil. Over the years, many scientists have reported such a set of curves, but there has not been a comprehensive review and comparison for different curve sets. The research spans several decades and is an important resource for electric utilities and insulation and testing equipment manufacturers. This paper gives an overview of the classic moisture equilibrium curves and their history and provides useful information on the relationships among them and their validity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the Transformer Operating Conditions for Evaluating the Dielectric Response

This paper presents an experimental investigation of transformer dielectric response and solid insulation water content. The dielectric response was carried out on the base of Hybrid Frequency Dielectric Spectroscopy and Polarization Current measurements method (FDS &PC). The calculation of the water content in paper is based on the water content in oil and the obtained equilibrium curves. A re...

متن کامل

Moisture solubility for differently conditioned transformer oils - Dielectrics and Electrical Insulation, IEEE Transactions on [see also Electrical Insulation, IEEE

It is important to monitor the moisture content of transformer oil in a transformer. One parameter of particular interest is the moisture solubility of transformer oil. It has been reported that transformer oils under different conditions have different solubility. Measurements of solubility for four different types of conditioned oil are presented in this paper: fresh Shell Diala AX oil, lab-a...

متن کامل

Estimation of Moisture in Transformer Insulation Using Dielectric Frequency Response Analysis by Heuristic Algorithms

Transformers are one of the most valuable assets of power systems. Maintenance and condition assessment of transformers has become one of the concerns of researchers due to huge number of transformers has been approached to the end of their lifetimes. Transformer’s lifetime depends on the life of its insulation and the insulation’s life is strongly influenced by its moisture attraction as well....

متن کامل

Separation of Ageing and Moisture Impacts on Transformer Insulation Degradation by Polarisation

This paper describes an accelerated ageing experiment of transformer oil/paper insulation with preset moisture levels. These samples were tested with return voltage and polarisation/depolarisation measurements. Molecular weight has also been measured with Gel Permeation Chromatography (GPC). Results suggested the impact of moisture on the ageing of oil/paper insulation. An attempt has been made...

متن کامل

ICSD 2007 – International Conference on Solid Dielectrics ( 9 th IEEE

The measurement of oil-paper insulation systems in the frequency domain provides novel diagnostic methods for quality control of materials and highvoltage power transformers. The first task is to measure and to analyse the dielectric behaviour of oil-paper insulation systems and their dependency on material quality, moisture content and ageing products in oil, paper and pressboard. Furthermore,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009