Optimization of the dosimetric leaf gap for use in planning VMAT treatments of spine SABR cases
نویسندگان
چکیده
The dosimetric leaf gap (DLG) is a beam configuration parameter used in the Varian Eclipse treatment planning system, to model the effects of rounded MLC leaf ends. Measuring the DLG using the conventional sliding-slit technique has been shown to be produce questionable results for some volumetric modulated arc therapy (VMAT) treatments. This study therefore investigated the use of radiochromic film measurements to optimize the DLG specifically for the purpose of producing accurate VMAT plans using a flattening-filter-free (FFF) beam, for use in treating vertebral targets using a stereotactic (SABR, also known as SBRT) fractionation schedule. Four test treatments were planned using a VMAT technique, to deliver a prescription of 24 Gy in 3 fractions to four different spine SABR treatment sites. Measurements of the doses delivered by these treatments were acquired using an ionization chamber and radiographic film. These measurements were compared with the doses calculated by the treatment planning system using a range of DLG values, including a DLG identified using the conventional sliding-slit method (1.1 mm). An optimal DLG value was identified, as the value that produced the closest agreement between the planned and measured doses (1.9 mm). The accuracy of the dose calculations produced using the optimized DLG value was verified using additional radiochromic film measurements in a heterogeneous phantom. This study provided a specific initial DLG (1.9 mm) as well as a film-based optimization method, which may be used by radiotherapy centers when attempting to commission or improve an FFF VMAT-based SABR treatment programme.
منابع مشابه
Dosimetric comparison of Acuros XB with collapsed cone convolution/superposition and anisotropic analytic algorithm for stereotactic ablative radiotherapy of thoracic spinal metastases
The aim of this study is to compare the recent Eclipse Acuros XB (AXB) dose calculation engine with the Pinnacle collapsed cone convolution/superposition (CCC) dose calculation algorithm and the Eclipse anisotropic analytic algorithm (AAA) for stereotactic ablative radiotherapy (SAbR) treatment planning of thoracic spinal (T-spine) metastases using IMRT and VMAT delivery techniques. The three c...
متن کاملComprehensive dosimetric planning comparison for early‐stage, non‐small cell lung cancer with SABR: fixed‐beam IMRT versus VMAT versus TomoTherapy
Volumetric-modulated arc therapy (VMAT) is emerging as a leading technology in treating early-stage, non-small cell lung cancer (NSCLC) with stereotactic ablative radiotherapy (SABR). However, two other modalities capable of deliver-ing intensity-modulated radiation therapy (IMRT) include fixed-beam and helical TomoTherapy (HT). This study aims to provide an extensive dosimetric compari-son amo...
متن کاملEvaluation of fluence‐based dose delivery incorporating the spatial variation of dosimetric leaf gap (DLG)
The Eclipse treatment planning system uses a single dosimetric leaf gap (DLG) value to retract all multileaf collimator leaf positions during dose calculation to model the rounded leaf ends. This study evaluates the dosimetric impact of the 2D variation of DLG on clinical treatment plans based on their degree of fluence modulation. In-house software was developed to retrospectively apply the 2D...
متن کاملDosimetric effects of immobilization devices on SABR for lung cancer using VMAT technique
The purpose of this study was to investigate the dosimetric effects of immobilization devices on the dose distributions of stereotactic ablative radiotherapy (SABR) for lung cancer using volumetric-modulated arc therapy (VMAT) technique. A total of 30 patients who underwent SABR for lung cancer were selected retrospectively. Every patient was immobilized using Body Pro-Lok with a vacuum bag cus...
متن کاملSensitivity analysis of physics and planning SmartArc parameters for single and partial arc VMAT planning
We investigate the sensitivity of various physics and planning SmartArc parameters to generate single and partial arc VMAT plans with equivalent or better plan quality as IMRT. Patients previously treated with step-and-shoot IMRT for several treatment sites were replanned using SmartArc. These treatment sites included head and neck, prostate, lung, and spine. Effect of various physics and plann...
متن کامل