New Opportunities for Charge Density Studies Using the FAST Area Detector*
نویسندگان
چکیده
The requirements for charge density studies of more complex molecules have been realized by use of the FAST area-detector diffractometer in conjunction with a rotating-anode generator, which allows to collect large quantities of diffraction data within less than two days, independent of unit cell size. Oxalic acid dihydrate has been chosen for test experiments. Data collection strategies are described and preliminary results are presented. These show that data of sufficiently high quality for charge density studies can be collected.
منابع مشابه
Low Settling Time All Digital DLL For VHF Application
Settling time is one of the most important parameter in design of DLLs. In this paper we propose a new high speed with low settling time Delay Locked Loop (DLL) in which a digital signal processor (DSP) is used instead of using phase-frequency detector, charge pump and loop filter in conventional DLL. To have better settling time, PRP conjugate gradient algorithm is used to optimize delay of ea...
متن کاملDFT studies of all fluorothiophenes and their radical cations as candidate monomers for conductive polymers
In this paper, electronic, structural, and spectroscopic properties of mono-, di-, tri-, andtetrafluorothiophenes and their radical cations are studied using the density functional theory andB3LYP method with 6-311++G** basis set. Also the effects of the number and position of thesubstituent on the electrochemical properties of the thiophene ring have been studied usingoptimized structures obta...
متن کاملAntimalarial Activity of some Conjugated Arylhydrazones: Ab Initio Calculation of Nuclear Quadrupole Coupling Constants (NQCC)
“Malaria” is a life-threatening blood disease in tropical regions that spreads by the bite of the Anopheles mosquito. Antimalarial medications are designed to cure or prevent this infection, and prosperous achievements in this area mostly depend on the knowing the drug-receptor interactions and active sites of medicine. This improvement can be achieved through understanding the electronic struc...
متن کاملFast System Matrix Calculation in CT Iterative Reconstruction
Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...
متن کاملA Fast, Robust, Automatic Blink Detector
Introduction “Blink” is defined as closing and opening of the eyes in a small duration of time. In this study, we aimed to introduce a fast, robust, vision-based approach for blink detection. Materials and Methods This approach consists of two steps. In the first step, the subject’s face is localized every second and with the first blink, the system detects the eye’s location and creates an ope...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012