Fatigue of the cement/bone interface: the surface texture of bone and loosening.
نویسندگان
چکیده
Loosening is recognized as one of the primary sources of total hip replacement (THR) failure. In this study the influence of the bone surface texture on loosening of the cement/bone interface was studied. Model cemented hip replacements were prepared and subjected to cyclic loads that induced pure shear fatigue of the cement/bone interface. The femoral canals were textured with the use of specific cutting tools to achieve a desired surface topography. Loosening of the implant with cyclic loading was characterized in terms of the initial migration (Region I), steady-state loosening (Region II), and unstable loosening (Region III). Results from the experiments showed that the initial migration and rate of steady-state loosening were dependent upon the bone surface topography. The apparent fatigue strength ranged from 0.8 to 5.1 MPa, and denotes the cyclic shear stress required for loosening of 1 mm within 10 million cycles. Regardless of the bone surface topography the ratio of apparent fatigue strength and ultimate shear strength of the interfaces was approximately 0.24. In general, the apparent fatigue strength increased proportional to the average surface roughness of the femoral canal and the corresponding volume available for cement interdigitation. In addition, there was a strong correlation between the normalized initial migration and the apparent fatigue strength (i.e., specimens with the highest initial migration exhibited the lowest fatigue strength).
منابع مشابه
The influence of surface topography on wear debris generation at the cement/bone interface under cyclic loading.
The long-term success of a total joint replacement can be undermined by loosening of the implant, generation of wear debris or a combination of both factors. In the present study the influence of the surface morphologies of the bone and cement mantle on loosening of cemented total joint replacements (THJRs) and development of wear debris were studied. Model cemented THJR specimens were prepared...
متن کاملSurface pretreatment for prolonged survival of cemented tibial prosthesis components: full- vs. surface-cementation technique
BACKGROUND One of few persisting problems of cemented total knee arthroplasty (TKA) is aseptic loosening of tibial component due to degradation of the interface between bone cement and metallic tibial shaft component, particularly for surface cemented tibial components. Surface cementation technique has important clinical meaning in case of revision and for avoidance of stress shielding. Degrad...
متن کاملCreep dominates tensile fatigue damage of the cement-bone interface.
Fatigue damage from activities of daily living has been considered to be a major cause of aseptic loosening in cemented total hip arthroplasty. The cement-bone interface is one region where loosening could occur, but to date the fatigue response of the interface has not been examined. Cement-bone specimens were prepared from fresh frozen human cadaver tissue using simulated in vivo conditions. ...
متن کاملEvaluating suppression of PGE2, PAF, and histamine synthesis and histopathological changes of bones in the membrane surrounding particulate polymethylmethacrylate in the rat tibia
Abstract Introduction: Inflammation and wear debris may be responsible for bone lysis and subsequent lost in aseptic arthroplasty. Prostaglandin E2, platelet activating factor, and histamine are important mediators of inflammatory cells. We studied histopathological changes of cement-bone interface after using specific antagonists of these mediators. Methods: Left and right tibiae...
متن کاملBone-cement interface of the glenoid component: stress analysis for varying cement thickness.
BACKGROUND Although shoulder arthroplasty is an accepted treatment for osteoarthritis, loosening of the glenoid component, which mainly occurs at the bone-cement interface, remains a major concern. Presently, the mechanical effect of the cement mantel thickness on the bone-cement interface is still unclear. METHODS Finite element analysis of a prosthetic scapula was used to evaluate the effec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical materials research. Part B, Applied biomaterials
دوره 76 2 شماره
صفحات -
تاریخ انتشار 2006