Copulsation balloon for right ventricular assistance: preliminary trials.

نویسندگان

  • D R Trumble
  • C S Park
  • J A Magovern
چکیده

BACKGROUND Options for management of acute right ventricular (RV) failure are limited. This report describes preliminary testing of a temporary RV assist device that acts by direct compression of the RV. The system comprises a pancake-shaped silicone balloon (5 cm diameter) connected to a drive console that delivers a 65-mL pneumatic pulse during cardiac systole. METHODS AND RESULTS Initial in vivo tests were performed on 6 pigs (weight, 41+/-4 kg). RV wall motion and stroke volume were monitored via transesophageal echocardiography. Acute RV failure was created by graded right coronary ligation, which yielded a 63% reduction in RV stroke volume (39.9+/-8.2 to 14.7+/-1.9 mL; P<0.002). We secured the balloon over the RV free wall by attaching it to the edges of the opened pericardium. The sternum was then reapproximated, and data were collected with the device off and on (every beat). Device placement had no deleterious effect on RV function. Balloon activation returned RV stroke volumes to normal (37.8+/-9.2 mL) and increased mean pulmonary artery pressures from 13+/-2 to 16+/-3 mm Hg (P<0.01). RV compression did not induce or exacerbate tricuspid regurgitation. Mean aortic pressure improved from postinfarction levels but did not return to normal. CONCLUSIONS We conclude that the pulmonary circulation can be supported in the short term via cardiac compression and that balloon copulsation techniques for short-term RV failure should be tested in long-term models.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Balloon Valvuloplasty for Neonatal Critical Pulmonary Valvar Stenosis with IVC Interruption: Pitfalls of the Transumbilical Approach

Transcatheter balloon pulmonary valvuloplasty (BPV) is considered to be the treatment of choice for neonates with critical pulmonary valvar stenosis (PVS) or pulmonary valvar atresia with intact ventricular septum accompanied by reasonable right ventricular volume. The percutaneous femoral venous access is the most preferred route for BPV in most cardiac centers. We report herein the case of a ...

متن کامل

Balloon dilatation of the pulmonary valve in the first year of life in patients with tetralogy of Fallot: a preliminary study.

Fifteen infants with tetralogy of Fallot, who would otherwise have required a palliative operation, underwent balloon dilatation of the right ventricular outflow tract. The mean period of palliation was 8.5 months (range 0-26 months). The procedure was performed without serious complications on 88% of occasions. This preliminary study suggests that balloon dilatation may be useful in the manage...

متن کامل

Integrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty

Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...

متن کامل

Extra-aortic balloon counterpulsation: an intraoperative feasibility study.

BACKGROUND Current methods of counterpulsation or ventricular assistance have significant vascular and limb complications. The aim of this study was to determine the safety and performance of a new method of non-blood-contacting counterpulsation using an inflatable cuff around the ascending aorta (extra-aortic balloon [EAB]). METHODS AND RESULTS In 6 patients undergoing first time off-pump co...

متن کامل

Growth of the pulmonary artery after neonatal balloon dilatation of the right ventricular outflow tract in an infant with the tetralogy of Fallot and atrioventricular septal defect.

A two week old girl with tetralogy of Fallot and atrioventricular septal defect underwent palliation, for severe hypoxaemia, by balloon dilatation to the right ventricular outflow tract. This procedure was repeated once over the next eight months without complications. Serial right ventricular angiograms showed growth of the hypoplastic pulmonary ring ("annulus"), trunk, and arteries. Balloon d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 99 21  شماره 

صفحات  -

تاریخ انتشار 1999