A comparison between real-time polymerase chain reaction and hybrid capture 2 for human papillomavirus DNA quantitation.

نویسندگان

  • Patti E Gravitt
  • Robert D Burk
  • Attila Lorincz
  • Rolando Herrero
  • Allan Hildesheim
  • Mark E Sherman
  • Maria Concepcion Bratti
  • Ana Cecilia Rodriguez
  • Kathy J Helzlsouer
  • Mark Schiffman
چکیده

Studies investigating human papillomavirus (HPV) viral load as a risk factor in the development of squamous intraepithelial lesions (SILs) and cancer have often yielded conflicting results. These studies used a variety of HPV viral quantitation assays [including the commercially available hybrid capture 2 (HC 2) assay], which differ in their ability to account for differences in cervical cell collection, linear dynamic range of viral load quantitation, and determination of type-specific versus cumulative viral load measures. HPV-16 and HPV-18 viral quantitation using real-time PCR assays were performed to determine whether type-specific viral load measurements that adjust for specimen cellularity result in a different association between viral load and prevalent SIL and cancer, compared with HC 2 quantitation (which does not adjust for cellularity or multiple infections). In general, HPV-16 viral load as measured by real-time PCR increased linearly with increasing grade of SIL while HPV-18 measured using similar techniques increased through low-grade SIL (LSIL), with HPV-18 viral load among high-grade SIL and cancers near the level of cytologically normal women. HC 2 viral load, using the clinical 1.0 pg/ml cut point, differentiated cytologically normal women from women with any level of cytological abnormality (normal versus >/=LSIL) but did not change as lesion severity increased. There was no evidence for plateau of HC 2 at high copy numbers, nor was significant variability in total specimen cellularity observed. However, cumulative viral load measurements by HC 2, in the presence of multiple coinfections, overestimated type-specific viral load. Multiple infections were more common among women with no (32%) or LSIL (51%) [versus 23% in high-grade SIL/cancer], partially explaining the lack of a dose response using a cumulative HC2 viral load measure. The nonrandom distribution of multiple infections by case-control status and the apparent differential effect of viral load by genotype warrant caution when using HC 2 measurements to infer viral load associations with SIL and cancer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

No Evidence for Human Papillomavirus in Patients with HIV in Iran

Background: Human Papillomaviruses (HPVs) have anestablished role in the development of cervical cancer. However, the presence of underlying conditions such as HIV/AIDS is necessary for this to occur. This studyaimed to evaluate the prevalence of HPV DNA in plasma samples from HIV-positive patients in Tehran, Iran. Methods: Plasma specimens from 95 patients diagnosed with HIV infection from Te...

متن کامل

Absence of Human Papillomavirus in Benign and Malignant Breast Tissue

Background & Objective: Malignant breast tumors, which are one of the most important deadly cancers in women, like many other cancers, are proposed to be related to viruses etiologically. Proper management of breast carcinoma necessitates an identification of the etiological factors. Human Papillomavirus is considered to have an etiological role in breast carcinoma. We...

متن کامل

Comparison of Hybrid Capture 2 Assay with Real-time-PCR for Detection and Quantitation of Hepatitis B Virus DNA

Background Both real-time-polymerase chain reaction (PCR) and hybrid capture 2 (HC2) assay can detect and quantify hepatitis B virus (HBV) DNA. However, real-time-PCR can detect a wide range of HBV DNA, while HC2 assay could not detect lower levels of viremia. The present study was designed to detect and quantify HBV DNA by real-time-PCR and HC2 assay and compare the quantitative data of these ...

متن کامل

Fetal RHD Genotyping Using Real-Time Polymerase Chain Reaction Analysis of Cell-Free Fetal DNA in Pregnancy of RhD Negative Women in South of Iran

Objective Maternal-fetal RhD antigen incompatibility causes approximately 50% of clinically significant alloimmunization cases. The routine use of prophylactic anti-D immunoglobulin has dramatically reduced hemolytic disease of the fetus and newborn. Recently, fetal RHD genotyping in RhD negative pregnant women has been suggested for appropriate use of anti-D immunoglobulin antenatal prophylaxi...

متن کامل

Diagnosis of human papillomatosis by polymerase chain reaction in cases of divergence between results of hybrid capture and papanicolaou cytology.

As various types of human papillomavirus (HPV) are involved in the pathogenesis of cervical cancer, correct diagnosis is of fundamental importance for screening programs. We evaluated the divergence of results between Papanicolaou cytology and hybrid capture by PCR detection of HPV DNA . A transversal study was conducted on 70 women attending private gynecological clinics in Brasilia, Brazil. P...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology

دوره 12 6  شماره 

صفحات  -

تاریخ انتشار 2003