Stability-indicative, validated, fast HPLC method for quantification of two genotoxic impurities in imatinib mesylate
نویسندگان
چکیده
The objective of the current study is to develop a validated, specific and stability-indicating reverse phase liquid chromatographic method for the quantitative determination of genotoxic impurities in the drug substance imatinib mesylate. This report includes a brief review of the toxicology of impurities in imatinib mesylate and the strategies used to set acceptance criteria for genotoxic impurities in imatinib mesylate. A preliminary examination of different approaches to determine genotoxic impurities in the drug substance imatinib mesylate susceptible to its presence either as residue from the synthesis or from degradation are described based on the toxicology studies. Controlling the impurities during drug development enhances product quality and minimizes risk with respect to safety to the patient. Recent regulatory guidance on genotoxic impurities require lower reporting, identification, and qualification limits but the overall impurity control strategy is also driven by appropriate “as low as reasonably practicable” (ALARP) procedures that include assessment of process capability and associated analytical development techniques. The bulk drug imatinib mesylate containing the two genotoxic impurities impurity-1 and impurity-2 are subjected to stress conditions of hydrolysis (acid and base), oxidation, photolysis and thermal degradation as per International Conference on Harmonization (ICH)-prescribed stress conditions to show the stability-indicating power of the method. These two genotoxic impurities are also observed as degradation impurities during acid and base hydrolysis. The chromatographic conditions are optimized using an impurity-spiked solution and the generated samples are used for forced degradation studies. In the developed HPLC method, the resolution between impurity-1, impurity-2 of imatinib mesylate is found to be greater than 2. The chromatographic separation is achieved on a Develosil C8 UG-5 150 mm x 4.6 mm, 5-μm column. The HPLC method employed a linear gradient elution, and the detection wavelength is set at 240 nm. The developed HPLC method is validated with respect to linearity, accuracy, precision and robustness.
منابع مشابه
Validation of an HPLC method for determination of imatinib mesylate in rat serum and its application in a pharmacokinetic study.
A simple, selective, and sensitive liquid chromatographic method has been developed and validated for quantitative determination of Imatinib mesylate in rat serum. Efficient chromatographic separation has been performed on a Zorbax Extend (5 microm, 4.6 x 250 mm) double end-capped C(18) column using a mobile phase consisting of methanol and aqueous triethyl amine (pH 10.5; 1%, v/v) (60:40, v/v)...
متن کاملQuantification of imatinib in human serum: validation of a high-performance liquid chromatography-mass spectrometry method for therapeutic drug monitoring and pharmacokinetic assays
BACKGROUND Imatinib mesylate has been a breakthrough treatment for chronic myeloid leukemia. It has become the ideal tyrosine kinase inhibitor and the standard treatment for chronic-phase leukemia. Striking results have recently been reported, but intolerance to imatinib and noncompliance with treatment remain to be solved. Molecular monitoring by quantitative real-time polymerase chain reactio...
متن کاملA Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form
A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...
متن کاملA Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form
A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...
متن کاملDevelopment and validation of a stability-indicating RP-HPLC method for the simultaneous estimation of process related impurities and degradation products of rasagiline mesylate in pharmaceutical formulation.
A sensitive, stability-indicating gradient reverse phase high-performance liquid chromatography-ultraviolet method has been developed for the quantitative determination of process-related impurities and forced degradation products of rasagiline mesylate in pharmaceutical formulation. Efficient chromatographic separation was achieved on an ACE C8, 150 × 4.6 mm, 3 µm column with mobile phase cont...