Highly sensitive analysis of sterol profiles in human serum by LC-ESI-MS/MS.
نویسندگان
چکیده
We have developed a highly sensitive and specific method for the analysis of serum sterol profiles. Sterols in 1 mul of dried serum were derivatized into picolinyl esters (3beta-picolinate) and analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) using the electrospray ionization (ESI) mode. In addition to cholesterol, 19 cholesterol precursors, cholestanol, campesterol, sitosterol, and sitostanol were identified simultaneously. Quantitative analyses for the picolinyl esters of 11 available sterols were performed, and detection limits were found to be less than 1 pg on-column. Reproducibilities and recoveries of 8 noncholesterol sterols were validated according to one-way layout and polynomial equation, respectively. The variances between sample preparations and between measurements by this method were calculated to be 1.6% to 8.2% and 2.5% to 16.5%, respectively. The recovery experiments were performed using 1 mul aliquots of normal human serum spiked with 1 ng to 6 ng of sterols, and recoveries of the sterols ranged from 88.1% to 102.5% with a mean recovery of 98.1%. The present method provides reliable and reproducible results for the identification and quantification of neutral sterols, especially in small volumes of blood samples, which is useful for serological diagnosis of inherited disorders in cholesterol metabolism and for noninvasive evaluation of cholesterol biosynthesis and absorption in humans.
منابع مشابه
A quick and Sensitive Liquid Chromatography–tandem Mass Spectrometry (LC-MS) Method for the Determination of Enalapril and Enalaprilat in Human Plasma: Application to a Bioequivalence Study
A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method for the estimation of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode was operated under the multiple-reaction monitoring mode. Sample pretreatment involved in a one-step protein precipitat...
متن کاملQuantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)
The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...
متن کاملLiquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma
A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...
متن کاملHighly sensitive quantification of 7alpha-hydroxy-4-cholesten-3-one in human serum by LC-ESI-MS/MS.
We describe a highly sensitive and specific method for the quantification of serum 7alpha-hydroxy-4-cholesten-3-one (C4), which has been used as a biomarker for bile acid biosynthesis. This method is based upon a stable isotope dilution technique by liquid chromatography-tandem mass spectrometry (LC-MS/MS). C4 was extracted from human serum (2-50 mul) by a salting-out procedure, derivatized int...
متن کاملMethod validation of clonidine hydrochloride in human plasma by LC-MS technique
A simple and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been evaluated for the assignment of clonidine hydrochloride in human plasma. The mobile phase composed of acetonitrile–water 60:40 (v/v), and 0.2% formic acid 20 µL of sample was chromatographically analyzed using a repacked ZORBAX-XDB-ODS C18 column (2.1 mm×30 m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of lipid research
دوره 49 9 شماره
صفحات -
تاریخ انتشار 2008