Computational method for high resolution spectral analysis of fractionated atrial electrograms
نویسندگان
چکیده
BACKGROUND The discrete Fourier transform (DFT) is often used as a spectral estimator for analysis of complex fractionated atrial electrograms (CFAE) acquired during atrial fibrillation (AF). However, time resolution can be unsatisfactory, as the frequency resolution is proportional to rate/time interval. In this study we compared the DFT to a new spectral estimator with improved time-frequency resolution. METHOD Recently, a novel spectral estimator (NSE) based upon signal averaging was derived and implemented computationally. The NSE is similar to the DFT in that both estimators model the autocorrelation function to form the power spectrum. However, as derived in this study, NSE frequency resolution is proportional to rate/period(2) and thus unlike the DFT, is not directly dependent on the window length. We hypothesized that the NSE would provide improved time resolution while maintaining satisfactory frequency resolution for computation of CFAE spectral parameters. Window lengths of 8s, 4s, 2s, 1s, and 0.5s were used for analysis. Two criteria gauged estimator performance. Firstly, a periodic electrogram pattern with phase jitter was embedded in interference. The error in detecting the frequency of the periodic pattern was determined. Secondly, significant differences in spectral parameters for paroxysmal versus persistent AF data, which have known dissimilarities, were determined using the DFT versus NSE methods. The parameters measured were the dominant amplitude, dominant frequency, and mean spectral profile. RESULTS At all time resolutions, the error in detecting the frequency of the repeating electrogram pattern was less for NSE than for DFT (p<0.001). The DFT was accurate to 2s time resolution/0.5 Hz frequency resolution, while the NSE was accurate to 0.5s time resolution/0.05 Hz frequency resolution. At all time resolutions, significant differences in the dominant amplitude spectral parameter for paroxysmal versus persistent CFAE were greater using NSE than DFT (p<0.0001). For three of five time resolutions, the NSE had greater significant differences than DFT for discriminating the dominant frequency and mean spectral profile parameters between AF types. CONCLUSIONS The results suggest that the NSE has improved performance versus DFT for measurement of CFAE spectral properties.
منابع مشابه
Improved frequency resolution for characterization of complex fractionated atrial electrograms
BACKGROUND The dominant frequency of the Fourier power spectrum is useful to analyze complex fractionated atrial electrograms (CFAE), but spectral resolution is limited and uniform from DC to the Nyquist frequency. Herein the spectral resolution of a recently described and relatively new spectral estimation technique is compared to the Fourier radix-2 implementation. METHODS In 10 paroxysmal ...
متن کاملSemi-supervised clustering of fractionated electrograms for electroanatomical atrial mapping.
BACKGROUND Electrogram-guided ablation procedures have been proposed as an alternative strategy consisting of either mapping and ablating focal sources or targeting complex fractionated electrograms in atrial fibrillation (AF). However, the incomplete understanding of the mechanism of AF makes difficult the decision of detecting the target sites. To date, feature extraction from electrograms is...
متن کاملElectrogram fractionation: the relationship between spatiotemporal variation of tissue excitation and electrode spatial resolution.
BACKGROUND Fractionated electrograms are used by some as targets for ablation in atrial and ventricular arrhythmias. Fractionation has been demonstrated to result when there is repetitive or asynchronous activation of separate groups of cells within the recording region of a mapping electrode(s). METHODS AND RESULTS Using a computer model, we generated tissue activation patterns with increasi...
متن کاملThe Relationship Between Spatiotemporal Variation of Tissue Excitation and Electrode Spatial Resolution
Background—Fractionated electrograms are used by some as targets for ablation in atrial and ventricular arrhythmias. Fractionation has been demonstrated to result when there is repetitive or asynchronous activation of separate groups of cells within the recording region of a mapping electrode(s). Methods and Results—Using a computer model, we generated tissue activation patterns with increasing...
متن کاملComparison of spectral estimators for characterizing fractionated atrial electrograms
BACKGROUND Complex fractionated atrial electrograms (CFAE) acquired during atrial fibrillation (AF) are commonly assessed using the discrete Fourier transform (DFT), but this can lead to inaccuracy. In this study, spectral estimators derived by averaging the autocorrelation function at lags were compared to the DFT. METHOD Bipolar CFAE of at least 16 s duration were obtained from pulmonary ve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computers in biology and medicine
دوره 43 10 شماره
صفحات -
تاریخ انتشار 2013