BACKGROUND AND PURPOSE Perfusion-weighted (PW) MRI is increasingly used to identify the tissue at risk. The adequate PW-MRI map and threshold remain controversial due to a considerable individual variation of values. By comparative positron emission tomography, we evaluated a simple MR-based and positron emission tomography-validated calibration of PW maps. METHODS PW-MRI and quantitative positron emission tomography (15O-water) of patients with acute stroke were used to calculate averaged as well as individual thresholds of penumbral flow (positron emission tomography cerebral blood flow (<20 mL/100 g/min) for maps of time to peak, mean transit time, cerebral blood flow, and cerebral blood volume. A linear regression analysis studied the variability of the individual thresholds using 3 different PW reference regions (hemispheric, white matter, gray matter). The best model was used for volumetric analysis to compare averaged and scaled individual thresholds and to calculate look-up tables for PW maps. RESULTS In 26 patients, the averaged thresholds were (median/interquartile range): cerebral blood flow 21.7 mL/100 g/min (19.9 to 32); cerebral blood volume 1.5 mL/100 g (0.9 to 1.8); mean transit time seconds 5.2 (3.9 to 6.9); and relative time to peak 4.2 seconds (2.8 to 5.8). The large individual variability was best explained by the mean value of the hemispheric reference derived from a region of interest on a level with the basal ganglia of the unaffected hemisphere (R(2): cerebral blood flow 0.76, cerebral blood volume 0.55, mean transit time 0.83, time to peak 0.95). Hemispheric reference-corrected thresholds clearly improved the detection of penumbral flow. Look-up tables were calculated to identify the individual thresholds according to the hemispheric reference value. CONCLUSIONS The individual variation of PW values, even if calculated by deconvolution, remains a major obstacle in quantitative PW imaging and can be significantly improved by a simple MR-based calibration. Easily applicable look-up tables identify the individual best threshold for each PW map to optimize mismatch detection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MRI perfusion maps in acute stroke validated with 15O-water positron emission tomography.

BACKGROUND AND PURPOSE Perfusion-weighted imaging maps are used to identify hypoperfusion in acute ischemic stroke. We evaluated maps of cerebral blood flow (CBF), cerebral blood volume, mean transit time, and time to peak (TTP) in acute stroke by comparison with positron emission tomography. METHODS Perfusion-weighted imaging and positron emission tomography were performed in 26 patients wit...

متن کامل

Multiparametric Model for Penumbral Flow Prediction in Acute Stroke.

BACKGROUND AND PURPOSE Identification of salvageable penumbra tissue by dynamic susceptibility contrast magnetic resonance imaging is a valuable tool for acute stroke patient stratification for treatment. However, prior studies have not attempted to combine the different perfusion maps into a predictive model. In this study, we established a multiparametric perfusion imaging model and cross-val...

متن کامل

Influence of the arterial input function on absolute and relative perfusion-weighted imaging penumbral flow detection: a validation with ¹⁵O-water positron emission tomography.

BACKGROUND AND PURPOSE Perfusion-weighted imaging maps are used to identify critical hypoperfusion in acute stroke. However, quantification of perfusion may depend on the choice of the arterial input function (AIF). Using quantitative positron emission tomography we evaluated the influence of the AIF location on maps of absolute and relative perfusion-weighted imaging to detect penumbral flow (...

متن کامل

Which time-to-peak threshold best identifies penumbral flow? A comparison of perfusion-weighted magnetic resonance imaging and positron emission tomography in acute ischemic stroke.

BACKGROUND AND PURPOSE In acute ischemic stroke, the hypoperfused but viable tissue is the main therapeutic target. In clinical routine, time-to-peak (TTP) maps are frequently used to estimate the hemodynamic compromise and to calculate the mismatch volume. We evaluated the accuracy of TTP maps to identify penumbral flow by comparison with positron emission tomography (PET). METHODS Magnetic ...

متن کامل

Comparison of the 2 Most Popular Deconvolution Techniques for the Detection of Penumbral Flow in Acute Stroke.

BACKGROUND AND PURPOSE Dynamic susceptibility-weighted contrast-enhanced (DSC) magnetic resonance imaging (MRI) is used to identify the tissue-at-risk in acute stroke, but the choice of optimal DSC postprocessing in the clinical setting remains a matter of debate. Using 15O-water positron emission tomography (PET), we validated the performance of 2 common deconvolution methods for DSC-MRI. ME...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 41 9  شماره 

صفحات  -

تاریخ انتشار 2010