Routine Maintenance of Centrifuges
ثبت نشده
چکیده
In general, handling centrifuges is a safe process, as long as high quality equipment is used, such as anodized or PTFE coated aluminum rotors for instance, and the following conditions are met: the centrifuges and their equipment are used properly, are in an undamaged condition and maintained as recommended here. Prevention from long-term exposure to residues like salts or aggressive chemicals through routine maintenance by customers themselves can help to largely avoid extensive corrosion incidents and to achieve the full lifetime of equipment. Therefore, instructions how centrifuges and their equipment can be cleaned, autoclaved, lubricated and decontaminated by the user himself are presented here. Finally, information is given in case professional inspection and certification services are required in labs with highest safety demands.
منابع مشابه
Guidelines (1988) for listing specifications of centrifuges
(1) Introduction (1.1) Centrifuges available for use in the clinical chemistry laboratory vary considerably in their complexity and safety. The Expert Panel considered that guidelines for the preparation of specifications in a standard format should be available to assist with the understanding ofuse of each instrument. The nomenclature used in the guidelines is defined in Appendix A. Quantitie...
متن کاملDid Stuxnet Take Out 1 , 000 Centrifuges at the Natanz Enrichment Plant ?
Although mechanical failures or operational problems have often been discussed as causing problems in the IR-1 centrifuges, the crashing of such a large number of centrifuges over a relatively short period of time could have resulted from an infection of the Stuxnet malware. This malicious code seeks to take over an industrial control system in order to destroy equipment while hiding its presen...
متن کاملIran’s Critical Capability in 2014: Verifiably Stopping Iran from Increasing the Number and Quality of its Centrifuges
Iran is expected to achieve a critical capability in mid-2014, which is defined as the technical capability to produce sufficient weapon-grade uranium from its safeguarded stocks of low enriched uranium for a nuclear explosive, without being detected. Iran would achieve this capability principally by implementing its existing, firm plans to install thousands more IR-1 centrifuges, and perhaps a...
متن کاملPreclinical Evaluation of 68Ga-MAA from Commercial Available 99mTc-MAA Kit
99mTc-Macroaggregated Albumin (99mTc-MAA) has been used as a perfusion agent. This study described development of the 68Ga-MAA via commercially available kits from Pars-Isotopes Company as a 99mTc-MAA kit. 68Ge/68Ga generator was eluted with suprapure HCl (0.6 M, 6 mL) in 0.5 mL fractions. The two fractions with the highest 68GaCl3 activity were generally used for labeling purposes. After label...
متن کاملApplications of Reliability Analyses of Standby
SOME APPLICATIONS OF RELIABILITY ANALYSES OF STANDBY REDUNDANT SYSTEMS WITH REPAIR Michikazu Kumagai , Toshiba Research & DeveZopment Center 169 Some applications are discussed concerning reliability analyses of a standby redundant system with repair. The system consists of a series subsystem composed of N identical units and n spares. Failed units are assumed to be repaired by r repair facilit...
متن کامل