Air bubbles and temperature effect on blood gas analysis.
نویسندگان
چکیده
The effect of temperature, time of storage, and presence of air bubbles in specimens for blood gas analysis was studied. The results show that air bubbles in a 10% proportion are undesirable because of significant elevation in the PO2, and the storage of anaerobic blood samples at room temperature (25 degrees C) is acceptable when measurements are done within the first 20 minutes.
منابع مشابه
Blood gas analysis: effect of air bubbles in syringe and delay in estimation.
Two common sources of error in blood pH and blood gas analysis were studied. The effect of delay in estimation was studied in 10 volunteers and 40 patients. Syringes were stored at 0 degree C, (crushed ice), 4 degrees C (refrigerator) and 22 degrees C (room temperature). The pressure of oxygen (PO2) fell significantly by 20 minutes at 4 degrees C and 22 degrees C but did not change significantl...
متن کاملEndogenous gas formation--an in vitro study with relevance to gas microemboli during cardiopulmonary bypass.
UNLABELLED Gas embolism is an identified problem during cardiopulmonary bypass (CPB). Our aim was to analyze the potential influence from gas solubility based on simple physical laws, here called endogenous gas embolism. Gas solubility decreases at higher temperature and gas bubbles are presumably formed at CPB warming. An experimental model to measure gas release was designed. Medium (water or...
متن کاملLiquid Temperature Effect on Sound Propagation in Polymeric Solution with Gas Bubbles
Acoustic properties of polymeric liquids are high sensitive to free gas traces in the form of fine bubbles. Their presence is typical for such liquids because of chemical reactions, small wettability of solid boundaries, trapping of air in technological operations, etc. Liquid temperature influences essentially its rheological properties, which may have an impact on the bubble pulsations and so...
متن کاملModeling and Optimization of Nano-bubble Generation Process Using Response Surface Methodology
In this paper, size distribution of nano-bubbles was measured by the reliable and fast method of laser diffraction technique. Nano-bubbles were produced using a nano-bubble generator designed and made based on hydrodynamic cavitation phenomenon in Venturi tubes. A Central Composite Design with Response Surface Methodology was used to conduct a five factor, five level factorial experimental desi...
متن کاملSurfactants reduce platelet-bubble and platelet-platelet binding induced by in vitro air embolism.
BACKGROUND The effect of gas bubbles on platelet behavior is poorly characterized. The authors assessed platelet-bubble and platelet-platelet binding in platelet-rich plasma in the presence and absence of bubbles and three surface-active compounds. METHODS Platelet-rich plasma was prepared from blood drawn from 16 volunteers. Experimental groups were surfactant alone, sparging (microbubble em...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 33 9 شماره
صفحات -
تاریخ انتشار 1980