Evaluation of criteria of manual blood smear review following automated complete blood counts in a large university hospital

نویسندگان

  • Samuel Ricardo Comar
  • Mariester Malvezzi
  • Ricardo Pasquini
چکیده

BACKGROUND There is great interest in reducing the number of automated complete blood counts requiring manual blood smear reviews without sacrificing the quality of patient care. This study was aimed at evaluating and establishing appropriate screening criteria for manual blood smear reviews to improve the performance in a hematology laboratory. METHOD A total of 1977 consecutive samples from the daily workload were used to evaluate four sets of screening criteria for manual blood smear reviews to identify samples with positive smear findings. Three sets of screening criteria were arbitrarily proposed in this study: Group 1 (narrow ranges), Group 2 (intermediate ranges), and Group 3 (wide limits) and one set (Group 4) was adapted from the International Society for Laboratory Hematology. All samples were run on Sysmex hematology analyzers and were investigated using manual blood smear reviews. Diagnostic accuracy and agreement were performed for each set of screening criteria, including an investigation of microscopic review rate and efficiency. RESULTS The microscopic review rates for Groups 1, 2, 3 and 4 were 73.85%, 54.52%, 46.33% and 46.38%, respectively; the false-negative rates were 0.50%, 1.97%, 2.73% and 3.95%, respectively. The efficiency and negative predictive values of Group 3 were 73.04% and 4.91%, respectively. CONCLUSIONS Group 3 had the best relationship between safety (false-negative rate: ≤3%) and efficiency to estimate the limits of automation in performing complete blood counts. This study strengthens the importance of establishing screening criteria for manual blood smear reviews, which account for the different contexts in which hematological determinations are performed. Each laboratory should optimize the screening criteria for manual blood smear reviews in order to maximize their efficiency and safety.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation and optimization of criteria for manual smear review following automated blood cell analysis in a large university hospital.

CONTEXT Each laboratory should have criteria for manual smear review that limit workload without affecting patient care. The International Consensus Group for Hematology Review established guidelines for action after automated blood cell analysis in 2005. OBJECTIVE To compare the consensus group criteria with our laboratory criteria and optimize them for better efficiency. DESIGN A total of...

متن کامل

Are the review criteria for automated complete blood counts of the International Society of Laboratory Hematology suitable for all hematology laboratories?

OBJECTIVE to verify whether the review criteria for automated blood counts suggested by the International Consensus Group for Hematology Review of the International Society for Laboratory Hematology are suitable for the Hematology Laboratory of Hospital de Clinicas, Universidade Federal do Paraná. METHODS initially, the review criteria of the International Society for Laboratory Hematology we...

متن کامل

Rate of manual leukocyte differentials in dog, cat and horse blood samples using ADVIA 120 cytograms

BACKGROUND Modern automated haematology instruments are capable of performing leukocyte differentials faster, cheaper and with a higher precision than the traditional 100-cell manual differential count. Thus, in human laboratories, criteria are defined for performing a manual review of the blood smear resulting in a marked reduction of manual differential counts. While common in human laborator...

متن کامل

The rate of manual peripheral blood smear reviews in outpatients.

BACKGROUND The International Consensus Group for Hematology Review recommends manual blood smears for new findings from automated complete blood cell (CBC) tests. However, in outpatients, the rate of peripheral manual blood smear reviews is uncertain, as is the effect of historical results on this rate. METHODS In a prospective cohort study of 687,955 members of a health maintenance organizat...

متن کامل

Purpose and Criteria for Blood Smear Scan, Blood Smear Examination, and Blood Smear Review

A microscopic examination of an appropriately prepared and well-stained blood smear by a knowledgeable laboratory professional is necessary and clinically useful in a number of circumstances and for a variety of reasons. In this article, an attempt is made to delineate the purpose and criteria for blood smear examination in a variety of circumstances that are encountered in everyday laboratory ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 39  شماره 

صفحات  -

تاریخ انتشار 2017