Automated assay of hexosaminidases in serum.

نویسندگان

  • J A Lowden
  • M A Skomorowski
  • F Henderson
  • M Kaback
چکیده

In serum there are two classes of hexosaminidase. One of these is heat-labile and is inactive in children with Tay-Sachs disease. Serum from heterozygotes for Tay-Sachs disease has half the normal activity of the heat-labile enzyme. The heat-labile enzyme can be inactivated by heating serum diluted in buffer for 5 mm at 60 #{176}C. We have used this property to develop a reliable, fully automated assay for serum hexosaminidases, which can be used for mass carrier screening programs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance characteristics of three automated immunoassays for thyroid hormones

Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...

متن کامل

Automated determination of serum hexosaminidase A by pH inactivation for detection of Tay-Sachs disease heterozygotes.

We have automated a manual test for detection of heterozygotes of Tay-Sachs disease by assay of hexosaminidase A in serum, based on pH inactivation [C/in. Chim. Acta 43, 417 (1973)]. The same manifold is used both for the total hexosaminidase and pH-inactivation (hexosaminidase B) procedures. Automation expedites mass screening of the Ashkenazi Jewish population for carriers of the TaySachs gen...

متن کامل

Quantitative Bacterial Micro-Assay for Rapid Diagnosis of Galactosemia: Application in Galactosemia Neonatal Screening

In the present study a new economic and rapid bacterial micro-assay for simultaneous detection and quantitative measurement of serum galactose was developed. Analysis of the standard curve showed a linearity range for galactose from 2 mg/dL to 180 mg/dL with a regression equation of Y = 0.013X ? 0.083; R² = 0.962. The advantage of the method is its ability to measure serum galactose quantitativ...

متن کامل

Automated Assay of Glycosidasesl

Automated methodology for monitoring the presence of one or more glycosidases in biological extracts has been described (l-7). These procedures require use of large amounts of synthetic glycoside(s) (l-4,6,7), compound automated systems (5), or extensive mechanical and/or electrical alterations of existing apparatus (8). The present paper describes a simple modification of the Technicon Basic A...

متن کامل

Kinetic determination of hexosaminidases for Tay-Sachs heterozygote screening.

We describe a method for continuous kinetic measurement of hexosaminidase activity, and have applied it to detection of heterozygotes for Tay-Sachs gene. In contrast to existing single-point methods, a ph of 4.5, which is optimal for hexosaminidase activity on the substrate (4-methylumbelliferyl-N-acetyl-beta-d-glucosaminide) is maintained while the increase in fluorescence produced by 4-methyl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 19 12  شماره 

صفحات  -

تاریخ انتشار 1973