Primary Calorimetric Results on Closed Pd|d2o Electrolysis Systems by Calvet Calorimetry

نویسندگان

  • Wu-Shou Zhang
  • Zhao-Fu Zhang
  • Zhong-Liang Zhang
چکیده

Anomalous heat absorption was observed in a closed Pd|D2O electrolysis system by Calvet calorimetry. The average excess power was – 14.6 mW over 105 hours period, which corresponds to a volume excess power of – 10.3 W/cm Pd and heat absorption of 3.81 MJ/cm Pd or 350 eV/atom Pd.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Third International Conference on Cold Fusion

Most of the laboratories involved with the question of excess enthalpy in Pd-D2O electrolysis experiments have employed isoperibolic calorimetric techniques. A careful re-examination of earlier results from several laboratories (California Institute of Technology, Massachusetts Institute of Technology, and Harwell Laboratory) is needed in terms of our present understanding of electrochemical ca...

متن کامل

Characteristics of Excess Heat in Pd|D2O+D2SO4 Electrolytic Cells Measured by Seebeck Envelope Calorimetry

Pre-electrolysis at the boiling point in open Pd|D2O cells is an effective method to activate a palladium cathode, which can produce excess power in subsequent electrolysis in closed systems for several months. The reproducibility is 23/45. Another characteristic of excess heat is the apparent resistance of electrolytic cell changes irreversibly with temperature.

متن کامل

Methods of Generating Excess Heat with the Pons and Fleischmann Effect: Rigorous and Cost Effective Calorimetry, Nuclear Produ

The results from a growing number of laboratories suggest that the Pons and Fleischmann effect (the production of "excess heat" during the electrolysis of D2O at palladium electrodes) is real. More over data from these laboratories indicate that excess heat events are accompanied by He production. Excess heat generation appears to depend on a number of factors: the quality — nature — of the cat...

متن کامل

Electrochemical Calorimetric Studies of the Cold Fusion Effect

Several types of calorimetric cell designs were used in attempts to measure excess enthalpy during the electrolysis of LiOD/D2O using palladium cathodes. Control experiments were run by using light water in place of D2O or by using platinum cathodes in place of palladium. Initial experiments using thin palladium cathodes of an unknown purity gave no significant differences between the Pd/D2O ce...

متن کامل

Measurements of Excess Heat in the Open Pd|D2O Electrolytic System by the Calvet Calorimetry

Excess heat was observed in the Pd|D2O electrolytic system using a Calvet type microcalorimeter. It was found that the average excess power was 0.025 W over 79 hours period. This result corresponds to a volume excess power of 8.75 W /cm Pd or a surface excess power of 0.044 W /cm Pd, and a specific excess heat of 2.48 MJ/cm Pd or 228 eV/atom Pd. The current density and D/Pd ratio for excess pow...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003