[Pattern-reversal electroretinogram (PERG): a normative study in adults].
نویسندگان
چکیده
PURPOSE To determine normative values for pattern-reversal electroretinogram (PERG) in healthy adult volunteers according to the standard protocol recommended by the International Society for Clinical Electrophysiology of Vision-ISCEV. METHODS Participants were 30 healthy volunteers (15 males) with ages from 18 to 61 years (mean= 30.8 +/- 8.7 yrs.; median= 29.5 yrs). Inclusion criteria were: visual acuity of 0.0 logMAR (20/20 Snellen) in each eye, absence of visual complaints, absence of media opacities, negative history for ocular or neurological diseases, negative family history for ocular and informed consent. PERG was recorded from each eye in a darkened room at 1 m from a high resolution display monitor. Stimuli were monochromatic checkerboards subtending 60, 15 e 7.5 minutes of visual angle reversing at 1.9 Hz. Responses were obtained from modified disposable fiber electrodes developed at UNIFESP. Latency (ms) for N35, P50 and N95 components as well as peak-to-peak amplitudes (microV) for N35-P50 and P50-N95 were determined. For normative values only one randomly chosen eye was included. Normal limits were calculated as 97.5% percentiles for latency and 2.5% percentile for amplitudes for each stimulus size. RESULTS Normal limits for N35, P50 and N95 latencies for 60', 15' and 7.5' stimuli were respectively: N35 - 40.1; 39.9 and 41.3 ms; P50 - 60.5; 64.4 and 65.6 ms and N95 - 103.4; 104.6 and 104.6 ms. For amplitude the normative values for N35-P50 and P50-N95 for 60', 15' and 7.5' were respectively: N35-P50 - 1.7; 1.6 and 0.9 microV; P50-N95 - 3.8; 2.8 and 1.5 microV. No gender differences were found either for latency or for amplitude in the three stimulus sizes. There was no correlation between PERG latency and amplitude with age, except for P50 amplitude for stimulus 15'(r=0.39; P=0.035). CONCLUSIONS Normative values were determined for PERG parameters of amplitude and latency for three stimulus sizes. These parameters are important for evaluating the normal functioning of retinal ganglion cells and the macula. The normative values obtained in this study are comparable to previous studies in the literature.
منابع مشابه
Three Dimensional Stimulus Source for Pattern Electroretinography in Mid- and Far-peripheral Retina
Purpose The pattern electroretinogram (pERG) response reflects, in part, ganglion cell function. However, probing retinal ganglion cell (RGC) function in the mid- and far peripheral retina is difficult with conventional flat-panel pERG stimulus sources. A pattern stimulus source is presented for probing the peripheral retina. Peripheral pERG (ppERG) responses were evaluated versus luminance, re...
متن کاملContrast sensitivity of the human pattern electroretinogram.
Contrast thresholds for the pattern electroretinogram (PERG) were measured using lock-in amplifier retrieval of the retinal signal and a swept contrast display. Contrast sensitivity functions (CSF) developed from these PERG contrast thresholds were compared with those established psychophysically under identical stimulus conditions. Whereas the PERG CSF showed a band-pass characteristic across ...
متن کاملRetinocortical time exhibits spatial selectivity.
We recorded simultaneous electroretinograms and visual evoked potentials to pattern-reversal stimulus in ten normal subjects employing check sizes subtending 7.5, 15, 30, 60, 120, 240 and 480 min of visual arc. The mean peak latency of the pattern electroretinogram (PERG) b wave decreased logarithmically with increasing check size. The mean peak latency of the pattern visual evoked potential (P...
متن کاملHemifield pattern electroretinogram in ocular hypertension: comparison with frequency doubling technology and optical coherence tomography to detect early optic neuropathy
BACKGROUND To assess the sensitivity and specificity of hemifield pattern electroretinogram (HF-PERG) for detecting early retinal ganglion cell (RGC) damage in ocular hypertensive (OH) patients. METHODS Fifty-two OH patients (mean age 56±9.6 years) with an intraocular pressure (IOP) .21 mmHg were assessed. All subjects underwent HF-PERG, optical coherence tomography (OCT), and frequency doubl...
متن کاملThe bioelectric field of the pattern electroretinogram in the mouse.
PURPOSE To compare the bioelectric field associated with the pattern electroretinogram (PERG) with that of the flash electroretinogram (FERG) in the mouse. METHODS PERGs and FERGs were recorded from each eye in 32 C57BL/6J mice using corneal silver loops referenced to a subcutaneous needle on the back of the head. PERG stimuli were horizontal gratings of 0.05 cycles per degree and 98% contras...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos brasileiros de oftalmologia
دوره 73 3 شماره
صفحات -
تاریخ انتشار 2010